Parameter Lists

5.2 Parameter Lists and Options, Software Version 8.10 (Standard)

5.2.1 0-** Operation / Display

Par.
Parameter description
No. #
0-0* Basic Settings
0-01
Language
0-02
Motor Speed Unit
0-03
Regional Settings
0-04
Operating State at Power-up (Hand)
0-09
Performance Monitor
0-1* Set-up Operations
0-10
Active Set-up
0-11
Edit Set-up
0-12
This Set-up Linked to
0-13
Readout: Linked Set-ups
0-14
Readout: Edit Set-ups / Channel
0-15
Readout: actual setup
0-2* LCP Display
0-20
Display Line 1.1 Small
0-21
Display Line 1.2 Small
0-22
Display Line 1.3 Small
0-23
Display Line 2 Large
0-24
Display Line 3 Large
0-25
My Personal Menu
0-3* LCP Custom Readout
0-30
Unit for User-defined Readout
0-31
Min Value of User-defined Readout
0-32
Max Value of User-defined Readout
0-33
Source for User-defined Readout
0-37
Display Text 1
0-38
Display Text 2
0-39
Display Text 3
0-4* LCP Keypad
0-40
[Hand on] Key on LCP
0-41
[Off] Key on LCP
0-42
[Auto on] Key on LCP
0-43
[Reset] Key on LCP
0-44
[Off/Reset] Key on LCP
0-45
[Drive Bypass] Key on LCP
0-5* Copy/Save
0-50
LCP Copy
0-51
Set-up Copy
0-6* Password
0-60
Main Menu Password
0-61
Access to Main Menu w/o Password
0-65
Personal Menu Password
0-66
Access to Personal Menu w/o Password
0-67
Bus Password Access
0-68
Safety Parameters Password
0-69
Password Protection of Safety Parameters
MG33MP02
Programming Guide
Default value
4-set-up
[0] English
1 set-up
ExpressionLimit
2 set-ups
ExpressionLimit
2 set-ups
[1] Forced stop, ref=old
All set-ups
0 %
All set-ups
[1] Set-up 1
1 set-up
[1] Set-up 1
All set-ups
[0] Not linked
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
ExpressionLimit
All set-ups
1614
All set-ups
1610
All set-ups
1613
All set-ups
1602
All set-ups
ExpressionLimit
1 set-up
[0] None
All set-ups
0 CustomReadoutUnit
All set-ups
100 CustomReadoutUnit
All set-ups
[240] Default Source
All set-ups
0 N/A
1 set-up
0 N/A
1 set-up
0 N/A
1 set-up
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
[1] Enabled
All set-ups
[1] Enabled
All set-ups
[0] No copy
All set-ups
[0] No copy
All set-ups
100 N/A
1 set-up
[0] Full access
1 set-up
200 N/A
1 set-up
[0] Full access
1 set-up
0 N/A
All set-ups
300 N/A
1 set-up
[0] Disabled
1 set-up
Danfoss A/S © 10/2018 All rights reserved.
FC 302
Change
Conver-
only
during
sion index
operation
TRUE
-
FALSE
-
FALSE
-
TRUE
-
TRUE
-1
TRUE
-
TRUE
-
FALSE
-
FALSE
0
TRUE
0
FALSE
0
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
0
TRUE
-
TRUE
-2
TRUE
-2
TRUE
-
TRUE
0
TRUE
0
TRUE
0
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
FALSE
-
FALSE
-
TRUE
0
TRUE
-
TRUE
0
TRUE
-
TRUE
0
TRUE
0
TRUE
-
Type
Uint8
Uint8
Uint8
5
5
Uint8
Uint16
Uint8
Uint8
Uint8
Uint16
Int32
Uint8
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Uint8
Int32
Int32
Uint8
VisStr[
25]
VisStr[
25]
VisStr[
25]
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Int16
Uint8
Int16
Uint8
Uint16
Uint16
Uint8
263