Parameter Descriptions
parameter 17-90 Absolute Position Mode and
parameter 17-91 Relative Position Mode.
Synchronization mode: High signal locks the
actual follower position to the actual master
position. The follower starts and catches up
with the master. Low signal stops the
synchronization and the follower makes a
controlled stop.
NOTICE
[114] Sync. to
Pos. Mode
This option is available only with
software version 48.XX.
Select positioning in synchronization mode.
NOTICE
[115] Home
Sensor
This option is available only with
software version 48.XX.
Normally open contact for defining the
home position. The function is defined in
parameter 17-80 Homing Function. Available
only at digital inputs 18, 32, and 33.
NOTICE
[116] Home
Sensor Inv.
This option is available only with
software version 48.XX.
Normally closed contact for defining the
home position. The function is defined in
parameter 17-80 Homing Function. Available
only at digital inputs 18, 32, and 33.
NOTICE
[117] Touch
Sensor
This option is available only with
software version 48.XX.
Normally open contact. Serves as a reference
for touch probe positioning. Available only at
digital inputs 18, 32, and 33.
NOTICE
[118] Touch
Sensor
This option is available only with
software version 48.XX.
Normally closed contact. Serves as a
reference for touch probe positioning.
Available only at digital inputs 18, 32, and
33.
NOTICE
[119] Speed
mode
This option is available only with
software version 48.XX.
Select the speed mode when [9] Positioning
or [10] Synchronization is selected in
parameter 1-00 Configuration Mode. Speed
reference is set by reference resource 1 or
fieldbus REF1 relative to
parameter 3-03 Maximum Reference.
[231] Power Limit
Select this option to activate the power limit
Mot.
function in the motor mode. See parameter
group 4-8* Power Limit.
[232] Power Limit
Select this option to activate the power limit
Gen.
function in the generating mode. See
parameter group 4-8* Power Limit.
MG33MP02
Programming Guide
[233] Power Limit
Both

5-10 Terminal 18 Digital Input

Option:
[0]
No operation
[1]
Reset
[2]
Coast inverse
[3]
Coast and reset inv
[4]
Quick stop inverse
[5]
DC-brake inverse
[6]
Stop inverse
[8]
Start
[9]
Latched start
[10]
Reversing
[11]
Start reversing
[12]
Enable start forward
[13]
Enable start reverse
[14]
Jog
[15]
Preset reference on
[16]
Preset ref bit 0
[17]
Preset ref bit 1
[18]
Preset ref bit 2
[19]
Freeze reference
[20]
Freeze output
[21]
Speed up
[22]
Speed down
[23]
Set-up select bit 0
[24]
Set-up select bit 1
[26]
Precise stop inverse
[27]
Precise start, stop
[28]
Catch up
[29]
Slow down
[34]
Ramp bit 0
[35]
Ramp bit 1
[40]
Latched precise start
[41]
Latch prec stop inv
[44]
Restart Drive
[51]
External Interlock
[55]
DigiPot increase
[56]
DigiPot decrease
[57]
DigiPot clear
[58]
DigiPot Hoist
[62]
Reset Counter A
[65]
Reset Counter B
[70]
Mech. Brake Feedb.
[71]
Mech. Brake Feedb. Inv.
Danfoss A/S © 10/2018 All rights reserved.
Select this option to activate the power limit
function in both the motor and the
generating mode. See parameter group 4-8*
Power Limit.
Function:
Functions are described in
parameter group 5-1* Digital
Inputs.
Functions are described in
parameter group 5-1* Digital
Inputs.
3
3
103