Parameter Lists
3-93
Maximum Limit
3-94
Minimum Limit
3-95
Ramp Delay
5.3.5 4-** Limits / Warnings
Par.
Parameter description
No. #
4-1* Motor Limits
4-10
Motor Speed Direction
5
5
4-11
Motor Speed Low Limit [RPM]
4-12
Motor Speed Low Limit [Hz]
4-13
Motor Speed High Limit [RPM]
4-14
Motor Speed High Limit [Hz]
4-16
Torque Limit Motor Mode
4-17
Torque Limit Generator Mode
4-18
Current Limit
4-19
Max Output Frequency
4-2* Limit Factors
4-20
Torque Limit Factor Source
4-21
Speed Limit Factor Source
4-23
Brake Check Limit Factor Source
4-24
Brake Check Limit Factor
4-25
Power Limit Motor Factor Source
4-26
Power Limit Gener. Factor Source
4-3* Motor Speed Mon.
4-30
Motor Feedback Loss Function
4-31
Motor Feedback Speed Error
4-32
Motor Feedback Loss Timeout
4-34
Tracking Error Function
4-35
Tracking Error
4-36
Tracking Error Timeout
4-37
Tracking Error Ramping
4-38
Tracking Error Ramping Timeout
4-39
Tracking Error After Ramping Timeout
4-4* Speed Monitor
4-43
Motor Speed Monitor Function
4-44
Motor Speed Monitor Max
4-45
Motor Speed Monitor Timeout
4-5* Adj. Warnings
4-50
Warning Current Low
4-51
Warning Current High
4-52
Warning Speed Low
4-53
Warning Speed High
4-54
Warning Reference Low
4-55
Warning Reference High
4-56
Warning Feedback Low
4-57
Warning Feedback High
4-58
Missing Motor Phase Function
4-59
Motor Check At Start
4-6* Speed Bypass
4-60
Bypass Speed From [RPM]
4-61
Bypass Speed From [Hz]
4-62
Bypass Speed To [RPM]
4-63
Bypass Speed To [Hz]
298
®
VLT
AutomationDrive FC 301/302
100 %
-100 %
ExpressionLimit
Default value
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
100 %
ExpressionLimit
ExpressionLimit
[0] No function
[0] No function
[0] DC-link voltage
98 %
[0] No function
[0] No function
ExpressionLimit
300 RPM
ExpressionLimit
ExpressionLimit
10 RPM
1 s
100 RPM
1 s
5 s
ExpressionLimit
300 RPM
0.1 s
0 A
ImaxVLT (P1637)
0 RPM
ExpressionLimit
-999999.999 N/A
999999.999 N/A
ExpressionLimit
ExpressionLimit
ExpressionLimit
[0] Off
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
Danfoss A/S © 10/2018 All rights reserved.
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
4-set-up
FC 302
Change
only
during
operation
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
x
TRUE
All set-ups
x
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
0
Int16
0
Int16
-3
TimD
Conver-
Type
sion index
-
Uint8
67
Uint16
-1
Uint16
67
Uint16
-1
Uint16
-1
Uint16
-1
Uint16
-1
Uint32
-1
Uint16
-
Uint8
-
Uint8
-
Uint8
0
Uint8
-
Uint8
-
Uint8
-
Uint8
67
Uint16
-2
Uint16
-
Uint8
67
Uint16
-2
Uint16
67
Uint16
-2
Uint16
-2
Uint16
-
Uint8
67
Uint16
-2
Uint16
-2
Uint32
-2
Uint32
67
Uint16
67
Uint16
-3
Int32
-3
Int32
-3
Int32
-3
Int32
-
Uint8
-
Uint8
67
Uint16
-1
Uint16
67
Uint16
-1
Uint16
MG33MP02