Parameter Descriptions
13-40 Logic Rule Boolean 1
Option:
Function:
ETR or [21] Advanced ETR. If warning
165, ATEX ETR freq.lim.warning is active,
the output is 1.
[94]
RS Flipflop 0
See parameter group 13-1*
Comparators.
[95]
RS Flipflop 1
See parameter group 13-1*
Comparators.
[96]
RS Flipflop 2
See parameter group 13-1*
Comparators.
[97]
RS Flipflop 3
See parameter group 13-1*
Comparators.
[98]
RS Flipflop 4
See parameter group 13-1*
Comparators.
[99]
RS Flipflop 5
See parameter group 13-1*
Comparators.
[100] RS Flipflop 6
See parameter group 13-1*
Comparators.
[101] RS Flipflop 7
See parameter group 13-1*
Comparators.
[102] Relay 1
[103] Relay 2
[104] Relay 3
X47/VLT
113.
[105] Relay 4
X47/VLT
113.
[106] Relay 5
X47/VLT
113.
[107] Relay 6
X47/VLT
113.
[108] Relay 7
X34/VLT
[109] Relay 8
X34/VLT
[110] Relay 9
X34/VLT
NOTICE
[222] Homing Ok
This option is available only with
software version 48.20 and
newer.
Homing is completed with the
selected homing function
(parameter 17-80 Homing Function).
NOTICE
[223] On Target
This option is available only with
software version 48.20 and
newer.
MG33MP02
Programming Guide
®
Extended Relay Card MCB
®
Extended Relay Card MCB
®
Extended Relay Card MCB
®
Extended Relay Card MCB
®
Relay Card MCB 105.
®
Relay Card MCB 105.
®
Relay Card MCB 105.
Danfoss A/S © 10/2018 All rights reserved.
13-40 Logic Rule Boolean 1
Option:
Function:
Positioning is completed and the on
target signal is sent when the actual
position is within parameter 3-05 On
Reference Window for the duration of
parameter 3-09 On Target Time and the
actual speed does not exceed
parameter 3-05 On Reference Window.
NOTICE
[224] Position Error
This option is available only with
software version 48.20 and
newer.
The position error exceeds the value
in parameter 4-71 Maximum Position
Error for the time set in
parameter 4-72 Position Error Timeout.
NOTICE
[225] Position Limit
This option is available only with
software version 48.20 and
newer.
The position is outside the limits set
in parameter 3-06 Minimum Position
and parameter 3-07 Maximum Position.
NOTICE
[226] Touch on Target
This option is available only with
software version 48.20 and
newer.
Target position is reached in touch
probe position mode.
NOTICE
[227] Touch Activated
This option is available only with
software version 48.20 and
newer.
Touch probe positioning active. The
frequency converter monitors the
touch probe sensor input.

13-41 Logic Rule Operator 1

Array [6]
Option:
Function:
st
Select the 1
logical operator to use on the
boolean inputs from parameter 13-40 Logic Rule
Boolean 1 and parameter 13-42 Logic Rule
Boolean 2.
Parameter numbers in square brackets stand
for the boolean inputs of parameters in
parameter group 13-** Smart Logic Control.
3
3
179