Danfoss VLT AutomationDrive FC 302 Programming Manual page 311

Hide thumbs Also See for VLT AutomationDrive FC 302:
Table of Contents

Advertisement

Parameter Lists
15-0* Operating Data
15-00 Operating hours
15-01 Running Hours
15-02 kWh Counter
15-03 Power Up's
15-04 Over Temp's
15-05 Over Volt's
15-06 Reset kWh Counter
15-07 Reset Running Hours Counter
15-1* Data Log Settings
15-10 Logging Source
15-11 Logging Interval
15-12 Trigger Event
15-13 Logging Mode
15-14 Samples Before Trigger
15-15 Service Log Sampling
15-2* Historic Log
15-20 Historic Log: Event
15-21 Historic Log: Value
15-22 Historic Log: Time
15-3* Fault Log
15-30 Fault Log: Error Code
15-31 Fault Log: Value
15-32 Fault Log: Time
15-33 Fault log: Date and Time
15-4* Drive Identification
15-40 FC Type
15-41 Power Section
15-42 Voltage
15-43 Software Version
15-44 Ordered Typecode String
15-45 Actual Typecode String
15-46 Frequency Converter Ordering No
15-47 Power Card Ordering No
15-48 LCP Id No
15-49 SW ID Control Card
15-50 SW ID Power Card
15-51 Frequency Converter Serial Number
15-53 Power Card Serial Number
15-54 Config File Name
MG33MP02
Programming Guide
0 h
All set-ups
0 h
All set-ups
0 kWh
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
[0] Do not reset
All set-ups
[0] Do not reset
All set-ups
0
2 set-ups
ExpressionLimit
2 set-ups
[0] False
1 set-up
[0] Log always
2 set-ups
50 N/A
2 set-ups
[0] Disabled
1 set-up
0 N/A
All set-ups
0 N/A
All set-ups
0 ms
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 s
All set-ups
ExpressionLimit
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
ExpressionLimit
All set-ups
Danfoss A/S © 10/2018 All rights reserved.
FALSE
74
Uint32
FALSE
74
Uint32
FALSE
75
Uint32
FALSE
0
Uint32
FALSE
0
Uint16
FALSE
0
Uint16
TRUE
-
Uint8
TRUE
-
Uint8
TRUE
-
Uint16
TRUE
-3
TimD
TRUE
-
Uint8
TRUE
-
Uint8
TRUE
0
Uint8
TRUE
-
Uint8
FALSE
0
Uint8
FALSE
0
Uint32
FALSE
-3
Uint32
FALSE
0
Uint16
FALSE
0
Int16
FALSE
0
Uint32
TimeO
FALSE
0
fDay
VisStr[
FALSE
0
6]
VisStr[
FALSE
0
20]
VisStr[
FALSE
0
20]
VisStr[
FALSE
0
5]
VisStr[
FALSE
0
40]
VisStr[
FALSE
0
40]
VisStr[
FALSE
0
8]
VisStr[
FALSE
0
8]
VisStr[
FALSE
0
20]
VisStr[
FALSE
0
20]
VisStr[
FALSE
0
20]
VisStr[
FALSE
0
10]
VisStr[
FALSE
0
19]
VisStr[
FALSE
0
16]
309
5
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vlt automationdrive fc 301

Table of Contents