5 Calibration

5.4.3 Installation locations for the calibration tools

5.4.3 Installation locations for the calibration tools
Location of fixed calibration items
The figure shows how the robot is equipped with items for installation of calibration
tools for Axis Calibration (fixed calibration pins and/or bushings). The figure does
not show installed calibration tools.
A fixed calibration pin and a bushing for the movable calibration tool are located
on each axis as follows.
xx1500000894
The fixed calibration pin for axis 1 is installed on a removable tower. The tower will
need to be removed if electronic position switches are fitted to the robot. Keep the
tower in a safe location for future recalibration needs and mark it with robot serial
number to ensure that the correct one is refitted.
Spare parts
When calibration is not being performed, a protective cover and an o-ring should
always be installed on the fixed calibration pin as well as a protective plug, included
a sealing, in the bushing. Replace damaged parts with new, if needed.
Spare part
Protection cover and plug set