4 Repair
4.6.1 Replacement of motor, axis 1
Continued
4
5
6
7
8
9
10
11
Refitting, motor axis 1
The procedure below details how to refit motor, axis 1.
1
2
Continues on next page
316
Action
Remove the cable gland cover at the cable exit by
unscrewing its two attachment screws.
Note
Make sure the gasket is not damaged!
Disconnect all connectors beneath the motor cover.
Apply lifting tool, motor axis 1, 4, 5 to the motor.
In order to release the brakes, connect the 24 VDC
power supply.
Remove the motor by unscrewing its four attach-
ment screws and plain washers.
If required, use the extension 300mm for bits 1/2".
CAUTION
The motor weighs 32 kg! All lifting equipment used
must be sized accordingly!
Lift the motor to get the pinion away from the gear
and disconnect the brake release voltage.
Remove the motor by gently lifting it straight up.
Action
DANGER
Turn off all:
electric power supply to the robot
hydraulic pressure supply to the robot
air pressure supply to the robot
Before entering the robot working area.
Make sure the o-ring on the circumference of the
motor is seated properly. Lightly lubricate the o-
ring with grease.
© Copyright 2007 - 2018 ABB. All rights reserved.
Note
xx0200000199
A: Cable gland cover
Art. no. is specified in
Required
equipment on page
314.
Connect to connector R2.MP1
+: pin 2
-: pin 5
Shown in the figure
Location of
motor on page
313.
Art. no. is specified in
Required
equipment on page
314.
Note
Art no. is specified in
Required
equipment on page
314.
Product manual - IRB 7600
3HAC022033-001 Revision: V

Advertisement

Table of Contents
loading

Table of Contents