Axis Calibration - Running The Calibration Procedure - ABB IRB 7600 Series Product Manual

Hide thumbs Also See for IRB 7600 Series:
Table of Contents

Advertisement

5.4.4 Axis Calibration - Running the calibration procedure

Required tools
The calibration tools used for Axis Calibration are designed to meet requirements
for calibration performance, durability and safety in case of accidental damage.
Equipment, etc.
Calibration tool box, Axis
Calibration
Required consumables
Consumable
Clean cloth
Spare parts
Spare part
Protection cover and plug set
Overview of the calibration procedure on the FlexPendant
The actual instructions of how to perform the calibration procedure and what to
do at each step is given on the FlexPendant. You will be guided through the
calibration procedure, step by step.
Use the following list to learn about the calibration procedure before running the
RobotWare program on the FlexPendant. It gives you a brief overview of the
calibration procedure sequence.
After the calibration method has been called for on the FlexPendant, the following
sequence will be run.
Product manual - IRB 7600
3HAC022033-001 Revision: V
5.4.4 Axis Calibration - Running the calibration procedure
WARNING
Calibrating the robot with Axis Calibration requires special calibration tools from
ABB. Using other pins in the calibration holes may cause severe damage to the
robot and/or personnel.
1 Choose calibration routine. The routines are described in
calibration procedure on page
2 Choose which axis/axes to calibrate.
3 The robot moves to synchronization position.
4 Validate the synchronization marks.
5 The robot moves to preparation position.
6 Remove the protective cover from the fixed pin and the protection plug from
the bushing, if any, and install the calibration tool.
© Copyright 2007 - 2018 ABB. All rights reserved.
Article number
Note
3HAC055412-001
Delivered as a set of calibration tools.
Required if Axis Calibration is the valid
calibration method for the robot.
Article number
-
Article number
3HAC056806-001
409.
5 Calibration
Note
Note
Contains replacement calibration
pin covers and protective plugs
for the bushing.
Routines in the
Continues on next page
413

Advertisement

Table of Contents
loading