Replacing The Smb Battery - ABB IRB 7600 Series Product Manual

Hide thumbs Also See for IRB 7600 Series:
Table of Contents

Advertisement

3 Maintenance

3.4.8 Replacing the SMB battery

3.4.8 Replacing the SMB battery
Continues on next page
204
Note
The battery low alert (38213 Battery charge low) is displayed when the battery
needs to be replaced. The recommendation to avoid an unsynchronized robot
is to keep the power to the controller turned on until the battery is to be replaced.
For a SMB board with 3-pole battery contact (RMU101 3HAC044168-001 or
RMU102 3HAC043904-001), the lifetime of a new battery is typically 36 months.
For a SMB board with 2-pole battery contact (DSQC), the typical lifetime of a new
battery is 36 months if the robot is powered off 2 days/week or 18 months if the
robot is powered off 16 h/day. The lifetime can be extended for longer production
breaks with a battery shutdown service routine. See Operating manual - IRC5
with FlexPendant for instructions.
WARNING
See instructions for batteries,
© Copyright 2007 - 2018 ABB. All rights reserved.
Safety risks during handling of batteries on page
40.
Product manual - IRB 7600
3HAC022033-001 Revision: V