ABB IRB 7600 Series Product Manual page 415

Hide thumbs Also See for IRB 7600 Series:
Table of Contents

Advertisement

2
3
4
Restarting an interrupted calibration procedure
If the Axis Calibration procedure is interrupted before the calibration is finished,
the RobotWare program needs to be started again. Use this procedure to take
required action.
Situation
The three-position enabling device on the
FlexPendant has been released during robot
movement.
Product manual - IRB 7600
3HAC022033-001 Revision: V
5.4.4 Axis Calibration - Running the calibration procedure
Action
All mechanical units connected to the system are
shown with their calibration status.
Tap the mechanical unit in question.
xx1500000943
Calibration method used at factory for each axis
is shown, as well as calibration method used for
the robot during last field calibration.
Tap Run Calibration Method. The software will
automatically call for the procedure for the valid
calibration method.
xx1500000944
Follow the instructions given on the FlexPendant.
© Copyright 2007 - 2018 ABB. All rights reserved.
Note
The FlexPendant will give all inform-
ation needed to proceed with Axis
Calibration.
A brief overview of the sequence
that will be run on the FlexPendant
is given in
Overview of the calibra-
tion procedure on the FlexPendant
on page
413.
Action
Press and hold the three-position enabling
device and press Play.
Continues on next page
5 Calibration
Continued
415