No.
Name/Value
46.33
Above torque limit
0.0 ... 1600.0%
46.42
Torque decimals
0...2
47

47 Data storage

47.01
Data storage 1
real32
See par.
47.31
47.02
Data storage 2
real32
See par.
47.32
47.03
Data storage 3
real32
See par.
47.33
47.04
Data storage 4
real32
See par.
47.34
47.05
Data storage 5
real32
See par.
47.35
47.06
Data storage 6
real32
See par.
47.36
47.07
Data storage 7
real32
See par.
47.37
Description
Defines the trigger level for "above limit" indication in torque
control. When actual torque exceeds the limit, bit 10 of
Drive status word 2
is set.
"Above limit" indication trigger level for torque control.
Defines the number of decimal places of torque-related
parameters.
Number of decimal places of torque parameters.
Data storage parameters that can be written to and read from
using other parameters' source and target settings.
Note that there are different storage parameters for different
data types. Integer-type storage parameters cannot be used
as the source of other parameters.
See also section
Data storage parameters
Data storage parameter 1.
Parameters
47.01...47.08
used as source values of other parameters.
Storage parameters
47.01...47.08
of received 16-bit data (parameter group
receive
data) or the source of transmitted 16-bit data
(parameter group
61 D2D and DDCS transmit
scaling and range are defined by parameters 47.31...47.38.
32-bit real (floating point) number.
Data storage parameter 2.
See also parameter
47.01 Data storage 1
32-bit real (floating point) number.
Data storage parameter 3.
See also parameter
47.01 Data storage 1
32-bit real (floating point) number.
Data storage parameter 4.
See also parameter
47.01 Data storage 1
32-bit real (floating point) number.
Data storage parameter 5.
See also parameter
47.01 Data storage 1
32-bit real (floating point) number.
Data storage parameter 6.
See also parameter
47.01 Data storage 1
32-bit real (floating point) number.
Data storage parameter 7.
See also parameter
47.01 Data storage 1
32-bit real (floating point) number.
(page 91).
are real 32-bit numbers that can be
can be used as the target
62 D2D and DDCS
data). The
real32.
real32.
real32.
real32.
real32.
real32.
Parameters 319
Def/FbEq16
300.0%
06.17
See par.
46.03
1
1 = 1
0.000
See par.
47.31
0.000
See par.
47.32
0.000
See par.
47.33
0.000
See par.
47.34
0.000
See par.
47.35
0.000
See par.
47.36
0.000
See par.
47.37