18

Mains choke selection

In common DC connections, the ACSM1 drive module(s) connected to AC
supply must be equipped with mains choke(s). Mains chokes are needed
to get the maximum DC power ratings from the ACSM1 drive module(s)
to reduce the AC input current (rms, peak) level
to meet the requirements for harmonic distortion
to balance the supply current in multiple AC input.

Mains choke data

Data for the mains chokes is given below.
Type
CHK-01
CHK-02
CHK-03
CHK-04
CHK-05
CHK-06
CHK-07
CHK-08
L :
I
:
th
I
: Maximum allowed short time current (rms). This current is allowed for
max
L
µH
6370
4610
2700
1475
1130
700
450
355
Mains choke nominal inductance
Maximum allowed continuous current (rms) at 55° C ambient
temperature
maximum 10 s.
Ith
Imax
A
A
4.2
6.2
7.6
11.4
13.1
19.6
22.0
26.3
33.1
52.6
47.1
74.0
63.0
98.8
84.5
140.0