ABB ACS880 Series Firmware Manual page 256

Industrial drives, primary control program
Hide thumbs Also See for ACS880 Series:
Table of Contents

Advertisement

256 Parameters
No.
Name/Value
DI2
DI3
DI4
DI5
DI6
DIO1
DIO2
FBA A MCW bit 7
EFB MCW bit 7
Other [bit]
31.12
Autoreset selection
Bit
Fault
0
Overcurrent
1
Overvoltage
2
Undervoltage
3
AI supervision fault
4
Supply unit
5...7
Reserved
8
Application fault 1 (defined in the application program)
9
Application fault 2 (defined in the application program)
10
Selectable fault (see parameter
11
External fault 1 (from source selected by parameter
12
External fault 2 (from source selected by parameter
13
External fault 3 (from source selected by parameter
14
External fault 4 (from source selected by parameter
15
External fault 5 (from source selected by parameter
0000h...FFFFh
Description
Digital input DI2
(10.02 DI delayed
Digital input DI3
(10.02 DI delayed
Digital input DI4
(10.02 DI delayed
Digital input DI5
(10.02 DI delayed
Digital input DI6
(10.02 DI delayed
Digital input/output DIO1
Digital input/output DIO2
Control word bit 7 received through fieldbus interface A.
Control word bit 7 received through the embedded fieldbus
interface.
Source selection (see
Terms and abbreviations
Selects faults that are automatically reset. The parameter is a
16-bit word with each bit corresponding to a fault type.
Whenever a bit is set to 1, the corresponding fault is
automatically reset.
The number and interval of reset attempts are defined by
parameters 31.14...31.16.
WARNING! Before you activate the function, make
sure that no dangerous situations can occur. The
function resets the drive automatically and continues
operation after a fault.
Notes:
• The autoreset function is only available in external control;
see section
Local control vs. external control
• Faults related to the Safe torque off (STO) function cannot
be automatically reset.
The bits of this binary number correspond to the following
faults:
31.13 User selectable
Automatic reset configuration word.
status, bit 1).
status, bit 2).
status, bit 3).
status, bit 4).
status, bit 5).
(11.02 DIO delayed
status, bit 0).
(11.02 DIO delayed
status, bit 1).
on page 112). -
(page 20).
fault)
31.01 External event 1
31.03 External event 2
31.05 External event 3
31.07 External event 4
31.09 External event 5
Def/FbEq16
3
4
5
6
7
10
11
30
32
0000h
source)
source)
source)
source)
source)
1 = 1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Acs880-01Acs880-37Acs880-04Acs880-07Acs880-17

Table of Contents