ABB ACS880 Series Firmware Manual page 312

Industrial drives, primary control program
Hide thumbs Also See for ACS880 Series:
Table of Contents

Advertisement

312 Parameters
No.
Name/Value
DIO1
DIO2
Other [bit]
44.13
Brake close delay
0.00 ... 60.00 s
44.14
Brake close level
0.00 ... 1000.00
rpm
44.15
Brake close level
delay
0.00 ... 10.00 s
44.16
Brake reopen delay
0.00 ... 10.00 s
44.17
Brake fault function
Fault
Warning
Description
Digital input/output DIO1
Digital input/output DIO2
Source selection (see
Terms and abbreviations
Defines a delay between a close command (that is, when the
brake control output is de-energized) and when the drive
stops modulating. This is to keep the motor live and under
control until the brake actually closes.
Set this parameter equal to the value specified by the brake
manufacturer as the mechanical make-up time of the brake.
Brake close delay.
Defines the brake close speed as an absolute value.
After motor speed remains below this level for the duration of
the brake close level delay
close command is given.
Note: Check the compatibility of this setting with
mode
(and the applicable deceleration time).
Brake close speed.
Defines a brake close level delay. See parameter
close
level.
Brake close level delay.
Defines a minimum time between brake closure and a
subsequent open command.
Brake reopen delay.
Determines how the drive reacts upon a mechanical brake
control error.
Note: If parameter
44.07 Brake acknowledge selection
to
No
acknowledge, acknowledgement status supervision is
disabled altogether and will generate no warnings or faults.
However, the brake open conditions are always supervised.
The drive trips on a
71A2 Mechanical brake closing failed
71A3 Mechanical brake opening failed
acknowledgement does not match the status presumed by
the brake control logic.
The drive trips on a
71A5 Mechanical brake opening not
allowed
fault if the brake open conditions cannot be fulfilled
(for example, the required motor starting torque is not
achieved).
The drive generates a
A7A1 Mechanical brake closing failed
A7A2 Mechanical brake opening failed
the acknowledgement does not match the status presumed
by the brake control logic.
The drive generates a
A7A5 Mechanical brake opening not
allowed
warning if the brake open conditions cannot be
fulfilled (for example, the required motor starting torque is not
achieved).
(11.02 DIO delayed
status, bit 0).
(11.02 DIO delayed
status, bit 1).
on page 112). -
(44.15 Brake close level
fault if the status of the
warning if the status of
Def/FbEq16
10
11
0.00 s
100 = 1 s
10.00 rpm
delay), a
21.03 Stop
See par.
46.01
44.14 Brake
0.00 s
100 = 1 s
0.00 s
100 = 1 s
Fault
is set
/
0
/
1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Acs880-01Acs880-37Acs880-04Acs880-07Acs880-17

Table of Contents