ABB ACS880 Series Firmware Manual page 329

Industrial drives, primary control program
Hide thumbs Also See for ACS880 Series:
Table of Contents

Advertisement

No.
Name/Value
Warning
50.33
FBA B comm loss
timeout
0.3 ... 6553.5 s
50.34
FBA B ref1 type
50.35
FBA B ref2 type
50.37
FBA B actual 1 type
50.38
FBA B actual 2 type
50.39
FBA B SW
transparent source
Not selected
Other
50.40
FBA B act1
transparent source
Not selected
Other
50.41
FBA B act2
transparent source
Not selected
Other
50.42
FBA B debug mode
Disable
Fast
Description
Drive generates an
A7C2 FBA B communication
This occurs even though no control is expected from the
fieldbus.
WARNING! Make sure that it is safe to continue
operation in case of a communication break.
Defines the time delay before the action defined by parameter
50.32 FBA B comm loss func
the communication link fails to update the message.
As a rule of thumb, this parameter should be set to at least 3
times the transmit interval of the master.
Time delay.
Selects the type and scaling of reference 1 received from
fieldbus adapter B.
See parameter
50.04 FBA A ref1
Selects the type and scaling of reference 2 received from
fieldbus adapter B.
See parameter
50.04 FBA A ref1
Selects the type/source and scaling of actual value 1
transmitted to the fieldbus network through fieldbus adapter
B.
See parameter
50.07 FBA A actual 1
Selects the type/source and scaling of actual value 2
transmitted to the fieldbus network through fieldbus adapter
B.
See parameter
50.08 FBA A actual 2
Selects the source of the fieldbus status word when the
fieldbus adapter is set to a transparent communication profile
eg. by its configuration parameters (group
No source selected.
Source selection (see
Terms and abbreviations
When parameter
50.37 FBA B actual 1 type
Transparent
or General, this parameter selects the source of
actual value 1 transmitted to the fieldbus network through
fieldbus adapter B.
No source selected.
Source selection (see
Terms and abbreviations
When parameter
50.38 FBA B actual 2 type
Transparent
or General, this parameter selects the source of
actual value 2 transmitted to the fieldbus network through
fieldbus adapter B.
No source selected.
Source selection (see
Terms and abbreviations
Enables the display of raw (unmodified) data received from
and sent to fieldbus adapter B in parameters 50.43...50.48.
This functionality should only be used for debugging.
Display of raw data from fieldbus adapter B disabled.
Display of raw data from fieldbus adapter B enabled.
warning.
is taken. Time count starts when
type.
type.
type.
type.
54 FBA B
settings).
on page 112). -
is set to
on page 112). -
is set to
on page 112). -
Parameters 329
Def/FbEq16
5
0.3 s
1 = 1 s
Auto
Auto
Auto
Auto
Not selected
-
Not selected
-
Not selected
-
Disable
0
1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Acs880-01Acs880-37Acs880-04Acs880-07Acs880-17

Table of Contents