Selection of constant speeds

By default, constant speeds 1...7 are selected using digital inputs DI4...DI6 as
follows:
DI4
DI5
DI6
0
0
0
1
0
0
0
1
0
1
1
0
0
0
1
1
0
1
0
1
1
1
1
1

Default parameter settings for the Sequential control macro

Below is a listing of default parameter values that differ from those listed for the
Factory macro in
Parameter listing
Parameter
No.
Name
20.12 Run enable 1 source
21.03 Stop mode
22.21 Constant speed function
22.22 Constant speed sel1
22.23 Constant speed sel2
22.24 Constant speed sel3
22.27 Constant speed 2
22.28 Constant speed 3
22.29 Constant speed 4
22.30 Constant speed 5
22.31 Constant speed 6
22.32 Constant speed 7
23.11
Ramp set selection
25.06 Acc comp derivation time
31.11
Fault reset selection
Constant speed active
None (External speed
reference used)
Constant speed 1
Constant speed 2
Constant speed 3
Constant speed 4
Constant speed 5
Constant speed 6
Constant speed 7
(page 115).
Sequential control macro
default
DIIL
Ramp
01b (Bit 0 = Packed)
DI4
DI5
DI6
600.00 rpm
900.00 rpm
1200.00 rpm
1500.00 rpm
2400.00 rpm
3000.00 rpm
DI3
0.12 s
Not selected