No.
Name/Value
Warning/Fault
37.11
ULC speed table
point 1
0.0 ... 30000.0 rpm
37.12
ULC speed table
point 2
0.0 ... 30000.0 rpm
37.13
ULC speed table
point 3
0.0 ... 30000.0 rpm
37.14
ULC speed table
point 4
0.0 ... 30000.0 rpm
37.15
ULC speed table
point 5
0.0 ... 30000.0 rpm
37.16
ULC frequency
table point 1
0.0 ... 500.0 Hz
37.17
ULC frequency
table point 2
0.0 ... 500.0 Hz
37.18
ULC frequency
table point 3
0.0 ... 500.0 Hz
37.19
ULC frequency
table point 4
0.0 ... 500.0 Hz
37.20
ULC frequency
table point 5
0.0 ... 500.0 Hz
Description
The drive generates a warning
warning) if the signal stays continuously below the underload
curve for half of the time defined by
timer.
The drive trips on
8001 ULC underload fault
continuously below the underload curve for the time defined
by
37.42 ULC underload
Defines the 1st speed point on the X-axis of the user load
curve.
The speed points are used in DTC motor control mode, and in
scalar motor control mode when speed control is being used.
The five points must be in order from lowest to highest. The
points are defined as positive values, but the range is
symmetrically effective also in the negative direction. The
monitoring is not active outside these two areas.
Speed.
Defines the 2nd speed point on the X-axis of the user load
curve.
Speed.
Defines the 3rd speed point on the X-axis of the user load
curve.
Speed.
Defines the 4th speed point on the X-axis of the user load
curve.
Speed.
Defines the 5th speed point on the X-axis of the user load
curve.
Speed.
Defines the 1st frequency point on the X-axis of the user load
curve.
The frequency points are used in scalar motor control mode
when frequency control is being used.
The five points must be in order from lowest to highest. The
points are defined as positive values, but the range is
symmetrically effective also in the negative direction. The
monitoring is not active outside these two areas.
Frequency.
Defines the 2nd frequency point on the X-axis of the user load
curve.
Frequency.
Defines the 3rd frequency point on the X-axis of the user load
curve.
Frequency.
Defines the 4th frequency point on the X-axis of the user load
curve.
Frequency.
Defines the 5th frequency point on the X-axis of the user load
curve.
Frequency.
(A8BF ULC underload
37.42 ULC underload
if the signal stays
timer.
Parameters 291
Def/FbEq16
3
150.0 rpm
1 = 1 rpm
750.0 rpm
1 = 1 rpm
1290.0 rpm
1 = 1 rpm
1500.0 rpm
1 = 1 rpm
1800.0 rpm
1 = 1 rpm
5.0 Hz
1 = 1 Hz
25.0 Hz
1 = 1 Hz
43.0 Hz
1 = 1 Hz
50.0 Hz
1 = 1 Hz
60.0 Hz
1 = 1 Hz