324 Parameters
No.
Name/Value
49.17
Minimum ext
frequency ref panel
-500.00 ... 500.00
Hz
49.18
Maximum ext
frequency ref panel
-500.00 ... 500.00
Hz
50
50 Fieldbus adapter
(FBA)
50.01
FBA A enable
Disable
Option slot 1
Option slot 2
Option slot 3
50.02
FBA A comm loss
func
No action
Fault
Last speed
Speed ref safe
Fault always
Description
Defines a minimum limit for control panel frequency reference
in external control.
In local control, the limits in parameter group
force. See section
Local control vs. external control
20).
Minimum frequency reference.
Defines a maximum limit for control panel frequency
reference in external control.
In local control, the limits in parameter group
force. See section
Local control vs. external control
20).
Maximum frequency reference.
Fieldbus communication configuration.
See also chapter
Fieldbus control through a fieldbus adapter
(page 533).
Enables/disables communication between the drive and
fieldbus adapter A, and specifies the slot the adapter is
installed into.
Communication between drive and fieldbus adapter A
disabled.
Communication between drive and fieldbus adapter A
enabled. The adapter is in slot 1.
Communication between drive and fieldbus adapter A
enabled. The adapter is in slot 2.
Communication between drive and fieldbus adapter A
enabled. The adapter is in slot 3.
Selects how the drive reacts upon a fieldbus communication
break. The time delay is defined by parameter
comm loss t
out.
No action taken.
Communication break detection active. Upon a
communication break, the drive trips on a
communication
fault and coasts to a stop.
Communication break detection active. Upon a
communication break, the drive generates a warning
FBA A
communication) and freezes the speed to the level the
drive was operating at. The speed is determined on the basis
of actual speed using 850 ms low-pass filtering.
WARNING! Make sure that it is safe to continue
operation in case of a communication break.
Communication break detection active. Upon a
communication break, the drive generates a warning
FBA A
communication) and sets the speed to the value
defined by parameter
22.41 Speed ref safe
reference is being used) or
frequency reference is being used).
WARNING! Make sure that it is safe to continue
operation in case of a communication break.
Drive trips on
7510 FBA A
though no control is expected from the fieldbus.
30 Limits
30 Limits
50.03 FBA A
7510 FBA A
(when speed
28.41 Frequency ref safe
communication. This occurs even
Def/FbEq16
-500.00 Hz
are in
(page
See par.
46.02
500.00 Hz
are in
(page
See par.
46.02
Disable
0
1
2
3
No action
0
1
2
(A7C1
3
(A7C1
(when
4