ABB ACS880 Series Firmware Manual page 373

Industrial drives, primary control program
Hide thumbs Also See for ACS880 Series:
Table of Contents

Advertisement

No.
Name/Value
90.53
Load gear
numerator
-2147483648 ...
2147483647
90.54
Load gear
denominator
-2147483648 ...
2147483647
90.55
Load feedback fault
Fault
Warning
90.56
Load position offset
-2147483648 ...
2147483647 rev
90.57
Load position
resolution
0...31
90.58
Pos counter init
value int
-2147483648 ...
2147483647
90.59
Pos counter init
value int source
Zero
Pos counter init
value int
Other
90.60
Pos counter error
and boot action
Request re-
initialization
Description
Parameters
90.53
and
90.54
the load (ie. driven equipment) speed and the encoder
feedback selected by parameter
selection. The gear can be used to correct a difference
between the load and encoder speeds for example if the
encoder is not mounted directly on the rotated machinery.
90.53 Load gear numerator
90.54 Load gear denominator
Load gear numerator.
See parameter
90.53 Load gear
Load gear denominator.
Selects how the drive reacts to loss of load feedback.
Drive trips on a
73A1 Load feedback
Drive generates an
A798 Encoder option comm loss
Load speed feedback
warning and continues operation using
estimated feedbacks.
Defines a load-side position offset. The resolution is
determined by parameter
Load-side position offset.
Defines how many bits are used for load position count within
one revolution. For example, with the setting of 16, the
position value is multiplied by 65536 for display in parameter
90.04 Load
position.
Load position resolution.
Defines an initial position (or distance) for the position counter
(as an integer value) when parameter
value int source
is set to
See also section
Position counter
Initial integer value for position counter.
Selects the source of the initial position integer value. When
the source selected by
90.67 Pos counter init cmd source
activates, the value selected in this parameter is assumed to
be the position of the load.
0.
Parameter
90.58 Pos counter init value
Source selection (see
Terms and abbreviations
Selects how the position counter reacts to loss of load
feedback.
Bit 4 of
90.35 Pos counter status
position counter is recommended.
define a gear function between
90.51 Load feedback
Load speed
=
Encoder speed
numerator.
fault.
90.57 Load position
resolution.
90.59 Pos counter init
Pos counter init value
int.
(page 53).
int.
on page 112). -
is cleared. Reinitialization of
Parameters 373
Def/FbEq16
1
-
1
-
Fault
0
or
A7B1
1
0 rev
-
16
-
0
-
Pos counter
init value int
0
1
Request re-
initialization
0