326 Parameters
No.
Name/Value
Position
50.08
FBA A actual 2 type
50.09
FBA A SW
transparent source
Not selected
Other
50.10
FBA A act1
transparent source
Not selected
Other
50.11
FBA A act2
transparent source
Not selected
Other
50.12
FBA A debug mode
Disable
Fast
50.13
FBA A control word
00000000h ...
FFFFFFFFh
50.14
FBA A reference 1
-2147483648 ...
2147483647
50.15
FBA A reference 2
-2147483648 ...
2147483647
Description
Motor position is sent as actual value 1. See parameter
Motor position
scaled.
Selects the type/source and scaling of actual value 2
transmitted to the fieldbus network through fieldbus adapter
A.
See parameter
50.07 FBA A actual 1
Selects the source of the fieldbus status word when the
fieldbus adapter is set to a transparent communication profile
eg. by its configuration parameters (group
No source selected.
Source selection (see
Terms and abbreviations
When parameter
50.07 FBA A actual 1 type
Transparent
or General, this parameter selects the source of
actual value 1 transmitted to the fieldbus network through
fieldbus adapter A.
No source selected.
Source selection (see
Terms and abbreviations
When parameter
50.08 FBA A actual 2 type
Transparent
or General, this parameter selects the source of
actual value 2 transmitted to the fieldbus network through
fieldbus adapter A.
No source selected.
Source selection (see
Terms and abbreviations
Enables the display of raw (unmodified) data received from
and sent to fieldbus adapter A in parameters 50.13...50.18.
This functionality should only be used for debugging.
Display of raw data from fieldbus adapter A disabled.
Display of raw data from fieldbus adapter A enabled.
Displays the raw (unmodified) control word sent by the
master (PLC) to fieldbus adapter A if debugging is enabled by
parameter
50.12 FBA A debug
This parameter is read-only.
Control word sent by master to fieldbus adapter A.
Displays raw (unmodified) reference REF1 sent by the master
(PLC) to fieldbus adapter A if debugging is enabled by
parameter
50.12 FBA A debug
This parameter is read-only.
Raw REF1 sent by master to fieldbus adapter A.
Displays raw (unmodified) reference REF2 sent by the master
(PLC) to fieldbus adapter A if debugging is enabled by
parameter
50.12 FBA A debug
This parameter is read-only.
Raw REF2 sent by master to fieldbus adapter A.
type.
51 FBA A
settings).
on page 112). -
is set to
on page 112). -
is set to
on page 112). -
mode.
mode.
mode.
Def/FbEq16
90.06
6
Auto
Not selected
-
Not selected
-
Not selected
-
Disable
0
1
-
-
-
-
-
-