Command Manual – NQA
H3C S9500 Series Routing Switches
Parameters
max-number: Maximum Number of test operations enabled simultaneously, in the
range 1 to 5.
Description
Use the nqa-agent max-requests command to set the maximum number of test
operations that can be enabled simultaneously.
Use the undo nqa-agent max-requests command to restore the default value.
By default, a maximum of 5 test operations can be enabled simultaneously.
Note:
If the configured value is smaller than the number of enabled test groups, the current
test is not stopped.
Examples
# Configure that the system can enable a maximum of 4 test operations simultaneously.
<H3C> system-view
System View: return to User View with Ctrl+Z.
[H3C] nqa-agent enable
[H3C] nqa-agent max-requests 4

1.1.13 probe-failtimes

Syntax
probe-failtimes times
undo probe-failtimes
View
NQA test group view
Parameters
times: Number of times of constant probe failures, in the range 1 to 15.
Description
Use the probe-failtimes command to set the number of consecutive probe failures
after which NQA will send the Trap information to the network management system.
Use the undo probe-failtimes command to restore the default value.