Command Manual – Clock Module
H3C S9500 Series Routing Switches
<H3C> system-view
System View: return to User View with Ctrl+Z.
[H3C] undo clock priority source 2
1.1.5 clock sa-bit
Syntax
clock sa-bit { sa4 | sa5 | sa6 | sa7 | sa8 } source source-no
undo clock sa-bit source source-no
View
System view
Parameters
source-no: Number of the Bits clock source, ranging from 1 to 2.
sa4: Time slot of sa4 bit.
sa5: Time slot of sa5 bit.
sa6: Time slot of sa6 bit.
sa7: Time slot of sa7 bit.
sa8: Time slot of sa8 bit.
Description
Use the clock sa-bit command to set the time slot of a Bits clock source.
Use the undo clock sa-bit command to restore the time slot of a Bits clock source to
the default value.
By default, the time slot of a Bits clock value is sa4.
sa4 to sa8 refer to the five bits, sa4 to sa8, of CRC4 multiple-frame even-frame time
slot 0, one of which can be selected by the carrier to carry the SSM information
according to ITU-T G.704.
Examples
# Set the time slot of Bits clock source 1 to sa5.
<H3C> system-view
System View: return to User View with Ctrl+Z.
[H3C] clock sa-bit sa5 source 1
# Restore the time slot of Bits clock source 1 to the default value, namely sa4.
<H3C> system-view
System View: return to User View with Ctrl+Z.
[H3C] undo clock sa-bit source 1