Command Manual – PoE
H3C S9500 Series Routing Switches
Description
Use the display supervision-module information command to display the name of
the supervision module, power supply model, specifications and output power, and
other information.
Examples
# Display current information about the power system
<H3C> display supervision-module information
Supervision Module Version
Supervision Module Name
Power Type
Power Rating Value
Power Current Value
Power Remaining Value : 2197 W
Power Peak Value
Power Average Value
PSU Number
PSU 1
Rating Output Power
Hard Version Info
PSU 2
Rating Output Power
Hard Version Info
Table 2-4 display supervision-module information command output description
Supervision Module Version
Supervision Module Name
Power Type
Power Rating Value
Power Current Value
Power Remaining Value
Power Peak Value
Power Average Value
Rating Output Power
: 2.0
:Spring Pms
:PSE4500-A
: 2250 W (220V)/1125 W(110V)
: 53 W
: 0 W
: 0 W
: 2
: 2500 W
:NP 2500
: 2500 W
:NP 2500
Field
Software version of the supervision module
Name of the supervision module
Power type
Rated power of the power system
Current consumption power of the power system
Current remaining power of the power system
Peak power of the power system
Average power of the power system
Rated output power. When one or two PSUs are
available, it is 2250 W for 220 VAC input and 1125
W for 110 VAC input. When three PSUs are
available, it is 4500 W for 220 VAC input and 2250
W for 110 VAC input.