Command Manual – PoE
H3C S9500 Series Routing Switches
2.1.2 display poe-power alarm
Syntax
display poe-power alarm
View
Any view
Parameters
None
Description
Use the display poe-power alarm command to display detailed alarm information
about the PoE PSUs.
Examples
# Display detailed alarm information about the PoE PSUs.
<H3C> display poe-power alarm
PSU alarm detail, PSU number : 2
PSU 1 alarm : NORMAL
PSU 2 alarm : NOTLINK
not in present
Table 2-2 display poe-power alarm command output description
Field
Alarm
Controller/Rectifier communication Fail/Rectifier
There can be the following alarm information:
NORMAL: Normal
NOTLINK: The controller fails to communicate with the module,
or the module is out of position.
INERROR: Module input failure (works abnormally; restore AC
power supply to solve this problem)
OUTERROR: Module input failure (works abnormally; restore
AC power supply to solve this problem)
HIGHVOL: Overvoltage of module (the module is powered off
due to overvoltage)
HIGHTEP: Overhigh temperature of module
FANERROR: Failure of fan
CLOSE: The module is powered off remotely.
CURLIMIT: Current limit in the module
2-2
Chapter 2 PoE PSU Supervision Commands
Description