reverse: Optional parameter, searches for the matching log information from the head
of the log buffer.
emergencies, alerts, critical, debugging, errors, informational, notifications,
warnings are the names of the eight log severity levels. You can type the values or
names of the desired severity levels, which are equivalent, in commands.
gives the details.
Table 1-2 Severity levels defined in the information center
Severity
emergencies
alerts
critical
errors
warnings
notifications
informational
debugging
size: Configures the size of buffer.
sizenum: Size of buffer (number of messages which can be kept); ranging from 1 to
1024. By default, the size of the buffer is 256.
|: Filters the configuration information to be output by regular expression.
begin: Optional parameter, displays all items beginning from the matching item.
exclude: Optional parameter, only displays the matching items.
include: Optional parameter, only displays the non-matching items..
text: Defines the regular expression.
Value
1
Information on system unavailability
2
Information requiring immediate reaction
3
Critical information
4
Error information
5
Warning information
6
Normal but important information
7
Notification that should be recorded
8
Information generated during the debugging
1-4