H3C S9500 Series Command Manual
H3C S9500 Series Command Manual

H3C S9500 Series Command Manual

Routing switches
Hide thumbs Also See for S9500 Series:

Advertisement

Quick Links

H3C S9500 Series Routing Switches
Command Manual
Hangzhou H3C Technologies Co., Ltd.
http://www.h3c.com
Manual Version: T2-08194H-20080520-C-2.03
Product Version: S9500-CMW520-R2132

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the S9500 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for H3C S9500 Series

  • Page 1 H3C S9500 Series Routing Switches Command Manual Hangzhou H3C Technologies Co., Ltd. http://www.h3c.com Manual Version: T2-08194H-20080520-C-2.03 Product Version: S9500-CMW520-R2132...
  • Page 2 Copyright © 2007-2008, Hangzhou H3C Technologies Co., Ltd. and its licensors All Rights Reserved No part of this manual may be reproduced or transmitted in any form or by any means without prior written consent of Hangzhou H3C Technologies Co., Ltd.
  • Page 3 About This Manual Related Documentation In addition to this manual, each H3C S9500 Series Routing Switches documentation set includes the following: Manual Description introduces installation procedure, S9500 Series Routing commissioning, maintenance and monitoring of Switches Installation Manual the S9500 series routing switches.
  • Page 4 Part Contents includes Multicast Routing and Forwarding Commands, IGMP Snooping Commands, IGMP Commands, PIM Multicast Commands, MSDP Commands, IPv6 Multicast Routing, Volume and Forwarding Commands, MLD Snooping Commands, MLD Commands, IPv6 PIM Commands, Multicast VLAN Commands. includes MPLS Basics Commands, MPLS TE Commands, MPLS VPLS Commands, MPLS L2VPN Commands, MPLS Volume...
  • Page 5 Convention Description Optional alternative items are grouped in square brackets [ x | y | ... ] and separated by vertical bars. One or none is selected. Alternative items are grouped in braces and separated by { x | y | ... } * vertical bars.
  • Page 6 Command Manual H3C S9500 Series Routing Switches OAA Volume Organization Manual Version T2-08194H-20080530-C-2.03 Product Version S9500-CMW520-R2132 Organization The OAA Volume is organized as follows: Features (command Description manual) OAP Module Introduces the commands for OAP module configuration. ACSEI Introduces the commands for ACSEI configuration.
  • Page 7 Command Manual – OAP Module H3C S9500 Series Routing Switches Table of Contents Table of Contents Chapter 1 OAP Module Configuration Commands ..............1-1 1.1 OAP Module Configuration Commands ................1-1 1.1.1 oap connect slot ...................... 1-1 1.1.2 oap reboot slot......................1-2...
  • Page 8 Command Manual – OAP Module H3C S9500 Series Routing Switches Chapter 1 OAP Module Configuration Commands Chapter 1 OAP Module Configuration Commands 1.1 OAP Module Configuration Commands 1.1.1 oap connect slot Syntax oap connect slot slot-number View User view Default Level...
  • Page 9 Command Manual – OAP Module H3C S9500 Series Routing Switches Chapter 1 OAP Module Configuration Commands 1.1.2 oap reboot slot Syntax oap reboot slot slot-number View User view Default Level 2: System level Parameters slot-number: Number of the slot where an OAP module resides.
  • Page 10: Table Of Contents

    Command Manual – ACSEI H3C S9500 Series Routing Switches Table of Contents Table of Contents Chapter 1 ACSEI Configuration Commands ................1-1 1.1 ACSEI Server Configuration Commands ................1-1 1.1.1 acsei client close ..................... 1-1 1.1.2 acsei client reboot ....................1-1 1.1.3 acsei server ......................
  • Page 11: Chapter 1 Acsei Configuration Commands

    Command Manual – ACSEI H3C S9500 Series Routing Switches Chapter 1 ACSEI Configuration Commands Chapter 1 ACSEI Configuration Commands 1.1 ACSEI Server Configuration Commands 1.1.1 acsei client close Syntax acsei client close client-id View ACSEI server view Default Level 2: System level Parameters client-id: ID of the ACSEI client to be closed.
  • Page 12: Acsei Server

    Command Manual – ACSEI H3C S9500 Series Routing Switches Chapter 1 ACSEI Configuration Commands Parameters client-id: ID of the ACSEI client to be restarted. Description Use the acsei client reboot command to restart the specified ACSEI client. Examples # Restart ACSEI client 1.
  • Page 13: Acsei Timer Clock-Sync

    Command Manual – ACSEI H3C S9500 Series Routing Switches Chapter 1 ACSEI Configuration Commands View System view Default Level 2: System level Parameters None Description Use the acsei server enable command to enable ACSEI server. Use the undo acsei server enable command to disable ACSEI server.
  • Page 14: Acsei Timer Monitor

    Command Manual – ACSEI H3C S9500 Series Routing Switches Chapter 1 ACSEI Configuration Commands By default, the clock sychronization timer is set to five minutes. Examples # Set the clock synchronization timer from ACSEI server to ACSEI client to 20 minutes.
  • Page 15 Command Manual – ACSEI H3C S9500 Series Routing Switches Chapter 1 ACSEI Configuration Commands undo debugging acsei server { all | error | event | packet } View User view Default Level 2: System level Parameters all: All ACSEI debugging.
  • Page 16: Debugging Acsei-Client

    Command Manual – ACSEI H3C S9500 Series Routing Switches Chapter 1 ACSEI Configuration Commands Field Description Packet type 0X01 represents registration packets. 0X02 represents information notifications. Type: MassagType 0X03 represents operation notifications. 0X04 represents monitoring packets. 0X05 represents deregistration packets.
  • Page 17 Command Manual – ACSEI H3C S9500 Series Routing Switches Chapter 1 ACSEI Configuration Commands View User view Default Level 2: System level Parameters all: All ACSEI client debugging. error: ACSEI client error debugging. event: ACSEI client event debugging. packet: ACSEI client packet debugging.
  • Page 18 Command Manual – ACSEI H3C S9500 Series Routing Switches Chapter 1 ACSEI Configuration Commands Field Description Discarding operation packet: status is The operation notification packet is not Open discarded because the client is disabled Discarding operation packet: client ID is...
  • Page 19 Command Manual – ACSEI H3C S9500 Series Routing Switches Chapter 1 ACSEI Configuration Commands Table 1-5 debugging acsei-client packet command output description Field Description Sending ACSEI packet ACSEI packets sent Receiving ACSEI packet ACSEI packets received Interface carrying ACSEI client (that is, interface...
  • Page 20: Display Acsei Client Info

    Command Manual – ACSEI H3C S9500 Series Routing Switches Chapter 1 ACSEI Configuration Commands Table 1-6 debugging acsei-client event command output description Field Description ACSEI Event Event debugging Status of client is RegSent The client is sending request Status of client is Closed...
  • Page 21 Command Manual – ACSEI H3C S9500 Series Routing Switches Chapter 1 ACSEI Configuration Commands <Sysname> display acsei client info 1 client ID: 1 client Description: Hardware: System Software: Application Software: CPU: Intel(R) Pentium(R) M processor 1.40GHz PCB Version: 3.00 CPLD Version: 1.00 Bootrom Version: 1.12...
  • Page 22: Display Acsei Client Summary

    Command Manual – ACSEI H3C S9500 Series Routing Switches Chapter 1 ACSEI Configuration Commands Table 1-7 display acsei client info command output description Field Description client ID ID of the ACSEI client client Description ACSEI client description Hardware Hardware version of the ACSEI client...
  • Page 23 Command Manual – ACSEI H3C S9500 Series Routing Switches Chapter 1 ACSEI Configuration Commands Examples # Display the summary of ACSEI client 1. <Sysname>display acsei client summary 1 client ID: 1 Status: Open MAC Address: 00e0-fc0a-c3ef Interface: GigabitEthernet5/1/1 Last registered: 02/08/2007 12:00:00 # Display the summary of all ACSEI clients.

This manual is also suitable for:

S9500-cmw520-r2132

Table of Contents