6.3 Communication via PROFINET

6.3
Communication via PROFINET
The Control Unit provides the following functions:
• IRT without isochronous mode
• MRP
• MRPD
• Diagnostic alarms
• Device replacement without
removable data storage medium
The Control Units have two RJ45 sockets that you can use to implement a line topology. You
can implement all topologies by using switches.
Additional information on PROFINET on the Internet
General information about PROFINET can be found at Industrial Communication
(http://www.automation.siemens.com/mcms/automation/en/industrial-
communications/profinet/Pages/Default.aspx).
The configuration of the functions is described in the PROFINET system description
(http://support.automation.siemens.com/WW/view/en/19292127) manual.
6.3.1

What do you need for communication via PROFINET?

Check the communication settings using the following table. If you answer "Yes" to the
questions, you have correctly set the communication settings and can control the inverter via
the fieldbus.
Questions
Is the inverter correctly connected to the
PROFINET?
Do the IP address and device name in the invert-
er and controller match?
Is the same telegram set in the inverter as in the
higher-level controller?
Are the signals that the inverter and the controller
exchange via PROFINET correctly interconnect-
ed?
178
Media redundancy, not bumpless with 200 ms
Precondition: Ring topology
Media redundancy, bumpless
Precondition: IRT and the ring topology created in the
control
According to error classes specified in the PROFIdrive
profile. See Activating diagnostics via the control
(Page 181).
Precondition: Topology created in the control
Answer/description
See: Connect the converter to PROFINET
(Page 179)
See: Configuring communication to the control
(Page 179)
Set the telegram in the inverter, see: Select tele-
gram (Page 180)
PROFIdrive-compliant interconnection in the
inverter, see: PROFIdrive profile for PROFIBUS
and PROFINET (Page 186)