Electrical installation
4.9 Other connections
4.9.7

Cabinet lighting with service socket (option L50)

Description
Option L50 includes cabinet lighting with an additional service socket for grounding socket-
outlet (connector type F) according to CEE 7/4. The power supply for the cabinet lighting and
the service socket is external and must be fuse-protected for max. 10 A.
It is an LED flashlight with an on/off switch, magnetic holders, and an approx. 3-m
connecting cable. In the as-delivered condition, the flashlight is already positioned at the
defined marks in the cabinet door and the connecting cable is wound on the holder.
Note
During operation of the cabinet unit, the cabinet lighting must remain attached in its position
on the cabinet door. The position on the cabinet door is marked by an adhesive label. The
connecting cable must be wound on its holder.
Connection
Table 4- 38
Terminal
Max. connectable cross-section: 4 mm
112
Terminal block X390 – connection for cabinet lighting with service socket
Designation
1
L1
2
N
3
PE
Technical data
230 V AC
power supply
Protective conductor
2