13. USING A LINEAR SERVO MOTOR
No.
Symbol
PC27 **COP9 Function selection C-9
The polarity setting of the encoder connected to the CN2A and CN2B connector
and the Z-phase connection judgement of the A/B/Z-phase input interface
encoder.
0
0 0
(3) Analog monitor
The servo status can be output to two channels in terms of voltage.
(a) Setting
Change the following digits of parameter No.PC09, PC10.
Parameters No.PC11 and PC12 can be used to set the offset voltages to the analog output voltages.
The setting range is between
Parameter No.
PC11
PC12
Name
Encoder pulse count polarity selection
0:
Linear servo motor positive direction and linear encoder
pulse increase direction
1:
Linear servo motor positive direction and linear encoder
pulse decrease direction
Parameter No.PC09
0
0
Analog monitor (MO1) output selection
(Signal output to across MO1-LG)
Analog monitor 1 (MO1) output axis selection
0: A-axis
1: B-axis
Parameter No.PC10
0
0
Analog monitor (MO2) output selection
(Signal output to across MO2-LG)
Analog monitor 2 (MO2) output axis selection
0: A-axis
1: B-axis
999 and 999mV.
Used to set the offset voltage for the analog monitor 1 (MO1).
Used to set the offset voltage for the analog monitor 2 (MO2).
13 - 48
Description
Factory
Setting
Setting
Unit
setting
Each
0000h
Refer to
axis
function
column.
Setting range [mV]
999 to 999
range
name
and