8. TROUBLESHOOTING
Warning No. E0
Warning description
Display
Name
E0.1
Excessive
regeneration
warning
Warning No. E1
Warning description
Display
Name
E1.1
Thermal overload
warning 1 during
operation
E1.2
Thermal overload
warning 2 during
operation
E1.3
Thermal overload
warning 3 during
operation
E1.4
Thermal overload
warning 4 during
operation
E1.5
Thermal overload
warning 1 during
a stop
E1.6
Thermal overload
warning 2 during
a stop
E1.7
Thermal overload
warning 3 during
a stop
E1.8
Thermal overload
warning 4 during
a stop
Name: Excessive regeneration warning
There is a possibility that regenerative power may exceed permissible regenerative power of built-in
regenerative resistor or regenerative option.
Cause
(1) Permissible regenerative
power of the built-in
regenerative resistor or
regenerative option is
over 85 .
Name: Overload warning 1
There is a possibility that overload alarm (50.1, 51. ) may occur.
Cause
(1) Load is 85
or larger of
the overload alarm (50.1)
alarm level.
(1) Load is 85
or larger of
the overload alarm (50.2)
alarm level.
(1) Load is 85
or larger of
the overload alarm (51.1)
alarm level
(1) Load is 85
or larger of
the overload alarm (50.3)
alarm level.
(1) Load is 85
or larger of
the overload alarm (50.4)
alarm level.
(1) Load is 85
or larger of
the overload alarm (50.5)
alarm level.
(1) Load is 85
or larger of
the overload alarm (51.2)
alarm level.
(1) Load is 85
or larger of
the overload alarm (50.6)
alarm level.
Stop method: Axes can operate (warning
detected at both axes)
Checkpoint
Check the regenerative
85
load ratio with MR
Configurator.
Stop method: Axes can operate (detected at
the corresponding axis)
Checkpoint
Examine checkpoints described in the alarm display "50.1".
Examine checkpoints described in the alarm display "50.2".
Examine checkpoints described in the alarm display "51.1".
Examine checkpoints described in the alarm display "50.3".
Examine checkpoints described in the alarm display "50.4".
Examine checkpoints described in the alarm display "50.5".
Examine checkpoints described in the alarm display "52.1".
Examine checkpoints described in the alarm display "50.6".
8 - 31
Finding
Action
or more.
Reduce the frequency
of positioning.
Increase the
deceleration time
constant.
Reduce the load.
Use a regenerative
option if not being
used.
Finding
Action