13. USING A LINEAR SERVO MOTOR
13.7 Troubleshooting
If an alarm/warning has occurred, refer to this chapter and remove its cause.
13.7.1 Alarms and warning list
When an error occurs during operation, the corresponding alarm or warning is displayed.
If any alarm has occurred, refer to section 13.7.2 and section 8.3; if any warning has occurred, refer to section
13.7.3 and section 8.4, and take the appropriate action. When an alarm occurs, ALM-A/ALM-B turns OFF.
After its cause has been removed, the alarm can be deactivated in any of the methods marked
deactivation column.
Display
10
Undervoltage
11
Switch setting error
12
Memory error 1 (RAM)
13
Clock error
15
Memory error 2 (EEP-ROM)
16
Encoder initial communication error 1
17
Board error
19
Memory error 3 (Flash-ROM)
1A
Motor combination error
1E
Encoder initial communication error 2
1F
Encoder initial communication error 3
20
Encoder normal communication error 1
21
Encoder normal communication error 2
24
Main circuit error
27
Initial magnetic pole detection error
28
Linear encoder error 2
2A
Linear encoder error 1
30
Regenerative error
31
Overspeed
32
Overcurrent
33
Overvoltage
34
SSCNET receive error 1
35
Command frequency error
36
SSCNET receive error 2
37
Parameter error
42
Linear servo control error
45
Main circuit device overheat
46
Linear servo motor overheat
47
Cooling fan error
50
Overload 1
51
Overload 2
52
Error excessive
8A
USB communication time-out error
8E
USB communication error
888
Watchdog
POINT
When an alarm with "Each axis" indicated in the "Stop method" column occurs, the
servo motor in the non-alarm-occurring axis can continue running.
Name
Alarm deactivation
Power
Error reset
OFF ON
(Note 1)
(Note 1)
(Note 2)
(Note 5)
(Note 1)
(Note 1)
(Note 1)
(Note 1)
(Note 1)
(Note 1)
(Note 1)
(Note 1)
13 - 58
in the alarm
Detection
method
CPU reset
(Note 3)
Common
Common
Common
Common
Common
Each axis
Common
Common
Each axis
Each axis
Each axis
Each axis
Each axis
Each axis
Each axis
Each axis
Each axis
(Note 1)
Common
Each axis
Each axis
Common
Each axis
Each axis
Each axis
Each axis
(Note 5)
Each axis
(Note 1)
Common
(Note 1)
Each axis
Common
(Note 1)
Each axis
(Note 1)
Each axis
Each axis
Common
Common
Common
Stop
method
(Note 4)
All axis
All axis
All axis
All axis
All axis
Each axis
All axis
All axis
Each axis
Each axis
Each axis
Each axis
Each axis
All axis
Each axis
Each axis
Each axis
All axis
Each axis
All axis
All axis
Each axis
Each axis
Each axis
Each axis
Each axis
All axis
Each axis
All axis
Each axis
Each axis
Each axis
All axis
All axis
All axis

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents