5. PARAMETERS
No.
Symbol
PB34
VRF2B Gain changing vibration suppression control resonance frequency setting
This parameter cannot be used in the speed control mode.
Set the resonance frequency for vibration suppression control when the gain
changing is valid. This parameter is made valid when the parameter No.PB02
setting is "
When using the vibration suppression control gain changing, always execute the
changing after the servo motor has stopped.
PB35
This parameter is not used. Do not change the value.
PB36
PB37
PB38
PB39
PB40
PB41
PB42
PB43
PB44
PB45
Name and function
2" and the parameter No.PB26 setting is "
1".
5 - 16
Factory
Setting
Unit
setting
Each
100.0
Hz
axis
0.00
0.00
100
0.0
0.0
0.0
1125
1125
0004h
0.0
0000h
Setting
range
0.1
to
100.0