5. PARAMETERS
No.
Symbol
PB13
NH1
Machine resonance suppression filter 1
Set the notch frequency of the machine resonance suppression filter 1.
When the parameter No.PB01 setting is "
is ignored.
If a value exceeding "3000" is set for this parameter, it is automatically rewritten
as "3000".
PB14
NHQ1
Notch shape selection 1
Select the shape of the machine resonance suppression filter 1.
0
When the parameter No.PB01 setting is "
is ignored.
PB15
NH2
Machine resonance suppression filter 2
Set the notch frequency of the machine resonance suppression filter 2.
Set parameter No.PB16 (notch shape selection 2) to "
parameter valid.
If a value exceeding "3000" is set for this parameter, it is automatically rewritten
as "3000".
PB16
NHQ2
Notch shape selection 2
Select the shape of the machine resonance suppression filter 2.
0
Name and function
0
Notch depth selection
Setting value
Depth
0
Deep
1
to
2
3
Shallow
Notch width
Setting value
Width
0
Standard
1
to
2
3
Wide
Machine resonance suppression filter 2 selection
0: Invalid
1: Valid
Notch depth selection
Setting value
Depth
0
Deep
1
to
2
3
Shallow
Notch width
Setting value
Width
0
Standard
1
to
2
3
Wide
0", the setting of this parameter
Gain
40dB
14dB
8dB
4dB
2
3
4
5
0", the setting of this parameter
1" to make this
Gain
40dB
14dB
8dB
4dB
2
3
4
5
5 - 13
Factory
Setting
Unit
setting
Each
4500
Hz
axis
Each
0000h
axis
Each
4500
Hz
axis
Each
0000h
axis
Setting
range
100
to
4500
Refer to
Name
and
function
column.
100
to
4500
Refer to
Name
and
function
column.