8. TROUBLESHOOTING
Display
50
Overload 1
51
Overload 2
52
Error excessive
8A
USB communication time-out error
8E
USB communication error
888
Watchdog
91
Main circuit device overheat warning
92
Battery cable disconnection warning
96
Home position setting warning
9F
Battery warning
E0
Excessive regeneration warning
E1
Overload warning 1
E3
Absolute position counter warning
E4
Parameter warning
E6
Servo forced stop warning
E7
Controller forced stop warning
E8
Cooling fan speed reduction warning
E9
Main circuit off warning
EB
The other axis fault warning
EC
Overload warning 2
ED
Output watt excess warning
Note 1. Deactivate the alarm about 30 minutes of cooling time after removing the cause of occurrence.
2. In some controller communication status, the alarm factor may not be removed.
3. Alarms and warnings are detected in the following axes.
Each axis: Alarms and warnings are detected in the A-axis and the B-axis separately.
Common: Alarms and warnings are detected in the A-axis and the B-axis together.
4. When an alarm or a warning occurs, the axes stop as below.
Each axis: Only the axis that detected the alarm or warning stops.
All axis: All axes stop.
5. The method is for enabled dynamic brake.
DB: Dynamic brake deceleration
EDB: Electronic dynamic brake deceleration
FR: Coasting
6. When an alarm or warning occurs during servo-on, the deceleration method will be electronic dynamic brake.
7. When Regenerative transistor error (30.2) or Regenerative transistor feedback data error (30.3) occurs, it will be FR.
8. When Overcurrent detected at hardware detection circuit (during operation) (32.1) or Overcurrent detected at hardware detection
circuit (during a stop) (32.3) occurs, it will be FR.
Name
Power
OFF ON
(Note 1)
(Note 1)
Alarm deactivation
Detection
Error reset CPU reset
(Note 1)
(Note 1)
Each axis Each axis
(Note 1)
(Note 1)
Each axis Each axis
Each axis Each axis
Common
Common
Common
Common
Each axis
Each axis
Each axis
Common
Each axis
Each axis
Each axis
Common
Common
Common
Common
Each axis
Each axis
Each axis
8 - 2
Deceleration method when
Stop
an alarm occurs (Note 5)
method
method
MR-J3W-
(Note 3)
(Note 4)
22B to MR-
J3W-1010B
DB
DB
DB
All axis
DB
All axis
DB
All axis
DB
All axis
DB
All axis
DB
All axis
DB
All axis
DB
MR-J3W-
0303BN6
(Note 6)
EDB
EDB
EDB
EDB
EDB
FR
EDB
EDB
FR
EDB

Hide quick links: