4. STARTUP
(b) Alarms
The following alarms and warning do not occur. However, the other alarms and warnings occur as when
the servo motor is connected.
Encoder initial communication error 1 (16. )
Encoder normal communication error 1 (20. )
Encoder normal communication error 2 (21. )
Absolute position erase (25. )
(2) Operating procedure
1) Switch off servo amplifier
2) Set parameter No.PC05 to "1", change test operation mode switch (SW2-1) to normal condition side
"Down", and then turn on the power supply.
3) Perform motor-less operation with the personal computer.
The display shows the following screen.
Battery cable disconnection warning (92.1)
Battery warning (9F.1)
Main circuit off warning (E9. )
8
SW1
ON 4E
TEST
SW2
1
2
Decimal point flickers.
4 - 13
Set SW2-1 to "DOWN"
SW2
UP
DOWN
1
2

Hide quick links: