Mitsubishi Electric MELSERVO-J3W Series Instruction Manual page 96

General-purpose ac servo, sscnet interface 2-axis ac servo amplifier
Hide thumbs Also See for MELSERVO-J3W Series:
Table of Contents

Advertisement

5. PARAMETERS
(1) For output pulse designation
Set "
0 " in parameter No.PC03.
Set the number of pulses per servo motor revolution.
Output pulse set value [pulses/rev]
For instance, set "5600" to Parameter No.PA15, the actually output A/B-phase pulses are as indicated
below.
A/B-phase output pulses
(2) For output division ratio setting
Set "
1 " in parameter No.PC03.
The number of pulses per servo motor revolution is divided by the set value.
Resolution per servo motor revolution
Output pulse
For instance, set "8" to Parameter No.PA15, the actually output A/B-phase pulses are as indicated below.
A/B-phase output pulses
(3) A/B-phase pulse electronic gear setting
This parameter is made valid when parameter No.PC03 is set to "
Set the encoder pulses (A/B-phase) output by the servo amplifier.
Set the encoder pulses output by the servo amplifier by parameter No.PA15 and parameter No.PA16.
Travel distance [pulse] of the linear encoder is multiplied by the set value.
Output pulse
Travel distance of linear encoder
The number of A/B-phase pulses actually output is 1/4 times greater than the preset number of pulses. Also,
the maximum output frequency is 4.6Mpps (after multiplication by 4). Use this parameter within the range.
When the set value is "0 (factory setting)", it is internally treated as "1".
5600
1400 [pulse]
4
Set value
262144
1
8192 [pulse]
8
4
5 - 9
[pulses/rev]
3 ".
Set value of parameter No.PA15
Set value of parameter No.PA16
[pulse]

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents