5. PARAMETERS
5.1.5 Using absolute position detection system
No.
Symbol
PA03
*ABS
Absolute position detection system
Set this parameter when using the absolute position detection system in the position control mode.
5.1.6 Forced stop input selection
No.
Symbol
PA04
*AOP1 Function selection A-1
The servo forced stop function is avoidable.
When not using the forced stop (EM1) of servo amplifier, set the selection of servo forced stop to Invalid ( 1
). At this time, the forced stop (EM1) automatically turns on inside the servo amplifier.
Parameter
Name
POINT
Turn off the power and then on again, or reset the controller after setting the
parameter to validate the parameter value.
This parameter cannot be used in the speed control mode.
Parameter No.PA03
0 0 0
Parameter
Name
POINT
Turn off the power and then on again, or reset the controller after setting the
parameter to validate the parameter value.
Parameter No.PA04
0
0
Each axis
Selection of absolute position detection system (refer to chapter 12)
0: Used in incremental system
1: Used in absolute position detection system
Common
0
Selection of servo forced stop
0: Valid (Forced stop (EM1) is used.)
1: Invalid (Forced stop (EM1) is not used.)
5 - 5
Factory
Setting
Unit
setting
0000h
Factory
Setting
Unit
setting
0000h
Setting
range
Refer to
the text.
Setting
range
Refer to
the text.