3. SIGNALS AND WIRING
(b) Output device
Device
Symbol
A-axis malfunction
ALM-A
B-axis malfunction
ALM-B
A-axis
MBR-A
electromagnetic
brake interlock
B-axis
MBR-B
electromagnetic
brake interlock
A-axis in-position
INP-A
B-axis in-position
INP-B
A-axis ready
RD-A
B-axis ready
RD-B
A-axis speed
SA-A
reached
B-axis speed
SA-B
reached
A-axis limiting
VLC-A
speed
B-axis limiting
VLC-B
speed
A-axis limiting
TLC-A
torque
B-axis limiting
TLC-B
torque
Connector
pin No.
CN3-11
ALM-A/ALM-B turns off when power is switched off or the protective circuit is
activated to shut off the base circuit.
Without alarm occurring, ALM-A/ALM-B turns on within about 1.5s after
CN3-24
power-on.
CN3-12
When using this signal, set operation delay time of the electromagnetic brake
in parameter No.PC02.
In the servo-off or alarm status, MBR-A/MBR-B turns off.
CN3-25
When using the signal, make it usable by the setting of parameter No.PD07
or PD09.
INP-A/INP-B turns on when the number of droop pulses is in the preset in-
position range. The in-position range can be changed using parameter
No.PA10.
When the in-position range is increased, INP-A/INP-B may be on conductive
status during low-speed rotation.
INP turns on when servo on turns on.
This signal cannot be used in the speed loop mode and the torque loop
mode.
When using the signal, make it usable by the setting of parameter No.PD07
or PD09.
RD-A/RD-B turns on when the servo is switched on and the servo amplifier is
ready to operate.
When using this signal, make it usable by the setting of parameter No.PD07
or PD09.
When the servo is off, SA will be turned OFF. When servo motor rotation
speed becomes approximately setting speed, SA-A/SA-B will be turned ON.
When the preset speed is 20r/min or less, SA-A/SA-B always turns on. This
signal cannot be used in the position loop mode and the torque loop mode.
When using this signal, make it usable by the setting of parameter No.PD07
or PD09.
VLC-A/VLC-B turns on when the servo motor speed reaches the speed set
with the controller in the torque loop mode. VLC-A/VLC-B turns off when the
servo turns off.
This signal cannot be used in position loop mode and the torque loop mode.
When using this signal, make it usable by the setting of parameter No.PD07
or PD09.
When torque is produced level of torque set with controller, TLC-A/TLC-B will
be turned ON. When the servo is off, TLC-A/TLC-B will be turned OFF.
This signal cannot be used in the torque loop mode.
Function/Application
3 - 14
I/O
division
DO-1
DO-1
DO-1
DO-1
DO-1
DO-1
DO-1