Mitsubishi Electric MELSERVO-J3W Series Instruction Manual page 481

General-purpose ac servo, sscnet interface 2-axis ac servo amplifier
Hide thumbs Also See for MELSERVO-J3W Series:
Table of Contents

Advertisement

APPENDIX
Parameter
No.
Po01
Function selection O-1
Axis selection for graphing analog data
Po02
(MR Configurator)
Axis selection for graphing digtal data (MR
Po03
Configurator)
Po04
Function selection O-2
Po05 to
This parameter is not used.
Po16
App. 1.2 Comparison of alarms and warnings
Warning
No.
10
Undervoltage
11
Switch setting error
12
Memory error 1 (RAM)
13
Clock error
15
Memory error 2 (EEP-ROM)
16
Encoder initial communication error 1
17
Board error
19
Memory error 3 (Flash-ROM)
1A
Motor combination error
1E
Encoder initial communication error 2
1F
Encoder initial communication error 3
20
Encoder normal communication error 1 Each axis Each axis
21
Encoder normal communication error 2 Each axis Each axis
24
Main circuit error
25
Absolute position erase
27
Initial magnetic pole detection error
28
Linear encoder error2
2A
Linear encoder error1
30
Regenerative error
31
Overspeed
32
Overcurrent
33
Overvoltage
34
SSCNET receive error 1
35
Command frequency error
36
SSCNET receive error 2
37
Parameter error
42
Linear servo control error
45
Main circuit device overheat
46
Servo motor overheat
47
Cooling fan error
50
Overload 1
51
Overload 2
52
Error excessive
8A
USB communication time-out error
8E
USB communication error
Name
Common New addition
Common New addition
Common New addition
Common New addition
Detection
Name
method
Common
Common
Common
Common
Common
Each axis Each axis
Common
Common
Each axis Each axis
Each axis Each axis
Each axis Each axis
Each axis All axis
Each axis Each axis
Each axis Each axis
Each axis Each axis
Each axis Each axis
Common
Each axis Each axis
Each axis All axis
Common
Each axis Each axis
Each axis Each axis
Each axis Each axis
Each axis Each axis
Each axis Each axis
Common
Each axis Each axis
Common
Each axis Each axis
Each axis Each axis
Each axis Each axis
Common
Common
Difference
Setting
from MR-J3-B
All-alarm all axis stop function is added.
Axis selection for analog data channels in MR
Configurator is added.
Axis selection for digital data channels in MR
Configurator is added.
Used for MR-J3W-0303BN6 servo amplifier.
None
Stop
Difference
method
from MR-J3-B
All axis
None
All axis
New alarm
All axis
All axis
All axis
None
All axis
All axis
New alarm
New alarm
None
New alarm
None
New alarm
New alarm
New alarm
All axis
All axis
None
New alarm
All axis
All axis
None
All axis
All axis
App. - 4
Comment
Comment Precautions
Occurs when the rotary switch or the DIP
switch setting is faulty.
Occurs when the cause of an alarm exists at
the encoder side.
Occurs when the encoder is not supported.
Occurs when the cause of an alarm exists at
the encoder side.
Alarm for the use with a linear servo motor.
Alarm for the use with a linear servo motor.
Alarm for the use with a linear servo motor.
Alarm for the use with a linear servo motor.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents