13. USING A LINEAR SERVO MOTOR
No.
Symbol
PS10
This parameter is not used. Do not change the value.
PS11
PS12
PS13
PS14
PS15
PS16
PS17
LTSTS Minute position detection method function selection
Used to set the response and the load to motor mass ratio of the minute position
detection method.
To make the parameter valid, set parameter No.PS08 (Linear function selection 3)
to "
0 0
PS18
IDLV
Minute position detection method identification signal amplitude
Used to set the identification signal amplitude for the minute position detection
method. To make the parameter valid, set parameter No.PS08 (Linear function
selection 3) to "
(4)(b) in section 13.5.2.)
PS19
This parameter is not used. Do not change the value.
PS20
PS21
PS22
PS23
PS24
PS25
PS26
Name
4" (minute position detection method). (Refer to (4)(b) in section 13.5.2.)
Response of the minute position detection method
Setting
Response
0
Low response
1
2
3
4
5
6
7
Medium response
Selecting the load to mass of the linear servo motor
primary side (coil) ratio, which decides the response of
the minute position detection method
Load to motor
Setting
mass ratio
0
Less than 10 times
1
10 times
2
20 times
3
30 times
4
40 times
5
50 times
6
60 times
7
70 times
4". Identification signal is "100 " when "0" is set. (Refer to
Setting
Response
8
Medium response
9
A
B
C
D
E
F
High response
Load to motor
Setting
mass ratio
8
80 times
9
90 times
A
100 times
B
110 times
C
120 times
D
130 times
E
140 times
F
150 times or more
13 - 56
Factory
Setting
Setting
Unit
setting
5
100
500
0000h
0
0000h
0000h
Each
0000h
Refer to
axis
function
column.
Each
0000h
axis
0000h
0000h
0000h
0000h
0000h
0000h
0000h
0000h
range
name
and
0000h
to
006Fh

Hide quick links: