5. PARAMETERS
5.2 Gain/filter parameters (No.PB
5.2.1 Parameter list
No.
Symbol
PB01
FILT
Adaptive tuning mode (Adaptive filter
PB02
VRFT
Vibration suppression control tuning mode
(advanced vibration suppression control)
PB03
This parameter is not used. Do not change the value.
PB04
FFC
Feed forward gain
PB05
This parameter is not used. Do not change the value.
PB06
GD2
Load to motor inertia moment ratio
PB07
PG1
Model loop gain
PB08
PG2
Position loop gain
PB09
VG2
Speed loop gain
PB10
VIC
Speed integral compensation
PB11
VDC
Speed differential compensation
PB12
This parameter is not used. Do not change the value.
PB13
NH1
Machine resonance suppression filter 1
PB14
NHQ1
Notch shape selection 1
PB15
NH2
Machine resonance suppression filter 2
PB16
NHQ2
Notch shape selection 2
PB17
Automatic setting parameter
PB18
LPF
Low-pass filter setting
PB19
VRF1
Vibration suppression control vibration frequency setting
PB20
VRF2
Vibration suppression control resonance frequency setting
PB21
This parameter is not used. Do not change the value.
PB22
PB23
VFBF
Low-pass filter selection
PB24
*MVS
Slight vibration suppression control selection
PB25
This parameter is not used. Do not change the value.
PB26
*CDP
Gain changing selection
PB27
CDL
Gain changing condition
PB28
CDT
Gain changing time constant
PB29
GD2B
Gain changing load to motor inertia moment ratio
PB30
PG2B
Gain changing position loop gain
PB31
VG2B
Gain changing speed loop gain
PB32
VICB
Gain changing speed integral compensation
PB33
VRF1B Gain changing vibration suppression control vibration frequency setting
PB34
VRF2B Gain changing vibration suppression control resonance frequency setting
)
POINT
The parameter whose symbol preceded by * can be validated with the following
conditions.
* : Turn off the power and then on again, or reset the controller after setting the
parameter.
The gain/filter parameters (No.PB
Name
)
) cannot be used in the torque loop mode.
5 - 10
Factory
Setting
setting
Unit
(Note 1)
(Note 2)
Each axis
0000h
Each axis
0000h
0
Each axis
0
500
Each axis
7.0
Multiplier
( 1)
Each axis
24
rad/s
Each axis
37
rad/s
Each axis
823
rad/s
Each axis
33.7
Each axis
980
0
Each axis
4500
Each axis
0000h
Each axis
4500
Each axis
0000h
Each axis
3141
rad/s
Each axis
100.0
Each axis
100.0
0.00
0.00
Each axis
0000h
Each axis
0000h
0000h
Each axis
0000h
Each axis
10
Each axis
1
Each axis
7.0
Multiplier
( 1)
Each axis
37
rad/s
Each axis
823
rad/s
Each axis
33.7
Each axis
100.0
Each axis
100.0
%
ms
Hz
Hz
Hz
Hz
ms
ms
Hz
Hz