Mitsubishi Electric MELSERVO-J3W Series Instruction Manual page 288

General-purpose ac servo, sscnet interface 2-axis ac servo amplifier
Hide thumbs Also See for MELSERVO-J3W Series:
Table of Contents

Advertisement

13. USING A LINEAR SERVO MOTOR
(2) List of details
No.
Symbol
PA01
**STY
Control mode
This parameter is set as "
To use a linear servo motor, set to "
Parameter No.PA01
0 0
PA03
*ABS
Absolute position detection system
Set this parameter when using the absolute position detection system in the
position control mode.
0 0 0
POINT
This parameter cannot be used in the speed control
mode.
PA10
INP
In-position range
Set the range, where in position (INP-A/INP-B) is output, in the command pulse
unit.
Command pulse
Droop pulses
In position (INP-A/INP-B)
POINT
This parameter cannot be used in the speed control
mode.
Name
0 " (rotary servo motor) in the initial setting.
4 ".
0
Control mode selection
0: Rotary servo motor
4: Linear servo motor
6: Direct drive motor
Selection of absolute position detection system (refer to chapter
12)
0: Used in incremental system
1: Used in absolute position detection system
If the absolute position detection system is enabled when the
linear encoder of the incremental type is being used,
parameter error (37.2) occurs.
Command pulse
ON
OFF
Servo motor droop pulses
In-position range [pulse]
13 - 39
Factory
Setting
Setting
Unit
setting
Each
0000h
Refer to
axis
function
column.
Each
0000h
Refer to
axis
function
column.
Each
100
pulse
axis
range
name
and
name
and
0
to
65535

Hide quick links:

Advertisement

Table of Contents
loading