Expert
Logger
User-defined protocol
l
User-defined input channel
l
User-defined output channel
l
Configuring LAN/WLAN/WWAN interfaces
LAN connection
l
WLAN connection (option)
l
WWAN connection (option)
l
USB interfaces
USB Device
l
USB Host (interface for USB memory)
l
4.12.1
SDI 12
SDI 12
The
"Configuring digital inputs" on page 105
(
There are two approaches to operate a sensor via
Manual creation (sensor address is required)
l
Automatic sensor detection
l
Manual creation via sensor address
Proceed as follows to create a connected
At the SDI 12 interface, create the channel for the SDI 12 master (SDI
l
master)
At the SDI 12 master, create the channel for the SDI 12 sensor (SDI
l
sensor)
At the SDI 12 sensor, create the data channels (SDI
l
Automatic sensor detection
You can also start an automatic search to detect the sensors connected via
SDI 12
At the
start the automatic search:
To perform a
SDI 12
4.12.1.1
SDI 12 Master
Create a channel for the SDI-12 Master from the context menu
Channel→ SDI-12 Master
Delphin Technology AG
interface is configured at the sensor terminals 33 and 34
automatically:
SDI 12
interface, create the channel for the
SDI 12
measurement, you must first connect at least one
measurement sensor to the sensor terminal 33 (D IN /
).
SDI 12
SDI 12
master
SDI 12
of the
interface.
182
SDI 12
:
sensor manually:
12 data)
SDI 12
master and
SDI 12
Create
Expert
Logger
Januar 2018
12
12
).
Manual
Need help?
Do you have a question about the Expert Logger and is the answer not in the manual?