Expert
Logger
Synchronous: Pulses are generated with a repetition rate based on the time.
l
If, for instance, a Cycle time is set at 15 minutes, pulses are generated at 00,
15, 30 and 45 minutes of each hour. As the pulses can only be generated
with an integer scaling factor, only discrete values can be selected.
In this mode, only certain times can be selected from the list as the cycles
represent integer scaling factors with respect to time.
Source
: In the trigger option
while the source is active. In the trigger option
starts with the edge of the source and runs continuously or until stopped
Reset
with
Pulse width: Sets the pulse duration, for example how long the pulse main-
tains a "High" level.
Cycle time: Sets the pulse repetition rate.
Reset
: Sets the output of the pulse generator immediately (asynchronous)
to "Low" level when the event occurs, unless
enabled, in which case it will go on until the current cycle is finished. If the
Level
trigger setting is selected, this signal permanently suppresses fur-
ther pulses occurring at the pulse generator output (as long as the respect-
ive level is applied).
Refer also to
Expert
Logger
Manual
Januar 2018
.
"Trigger options" on page 54
Level
, the pulse generator only operates
Edge
End of running cycle
.
123
, the pulse generator
is
Delphin Technology AG
Need help?
Do you have a question about the Expert Logger and is the answer not in the manual?