Interpreting T1 Or E1 Module Status Lights; Profiles Associated With A T1 Or E1 Module; Table 9-1 T1 And E1 Trunk Module Port Connector Status Lights - Lucent Technologies Stinger MRT 19 Getting Started Manual

Table of Contents

Advertisement

Configuring T1 and E1 Trunk Modules

Interpreting T1 or E1 module status lights

Inform your service provider that the equipment is connected so the provider can
activate the line.

Interpreting T1 or E1 module status lights

The RJ-48 connector for each port of the T1 or E1 trunk module is equipped with a
green and an orange status light. Table 9-1 explains the function of these status lights.
Table 9-1. T1 and E1 trunk module port connector status lights
Status
light
Orange
Green

Profiles associated with a T1 or E1 module

The following profiles are associated with a T1 or E1 module installed and configured
in a Stinger MRT.
Profile
DS1-ATM
DS1-ATM-Stat
Slot-Static-Config
9-4
Condition
Indicates
ON
An alarm condition exists—the line is out of
synchronization.
OFF
No alarm condition exists, or the port is inactive.
ON
The local and remote ends of the physical line have
achieved frame synchronization, and the local end of the
ATM link has achieved cell delineation.
OFF
The line is out of synchronization, or the port is inactive.
Description
Created by the system for each T1 or E1 link when a
module is installed. Use this profile to configure the
front-end framing and cell delineation features of a T1 or
E1 link. For more information, see "DS1-ATM profile" on
page 9-5.
Per-link IMA-specific parameters are stored in the
IMA-Option-Config subprofile of the line-config profile.
Created by the system for the T1 or E1 link when a module
is installed. Use this profile to determine the status and
statistics for an individual T1 or E1 link. For more
information, see "DS1-ATM-Stat profile" on page 9-11.
IMA-specific statistics are stored in the IMA-Link-Status
and IMA-Line-Statistic subprofiles.
Created by the system for the T1 or E1 module when a
module is installed. The t1e1-trunk-card-mode parameter
lets you configure the T1 or E1 trunk module to support
either T1 or E1 lines. For more information, see
"Slot-Static-Config profile" on page 9-14.
Stinger® MRT Getting Started Guide

Advertisement

Table of Contents
loading

This manual is also suitable for:

Stinger mrt 23

Table of Contents