Setting A Telnet Password - Lucent Technologies Stinger MRT 19 Getting Started Manual

Table of Contents

Advertisement

Connected to 1.1.1.1
Escape character is '^]'.
User: admin
Password: x1!35DPG

Setting a Telnet password

A Telnet password is a global, systemwide password required for Telnet logins to the
unit. The Telnet password is required before the system accepts the connection and
prompts for the username. Following are the default parameters associated with
Telnet logins to a Stinger unit:
[in IP-GLOBAL]
telnet-password = ""
user-profile = ""
Parameter
Telnet-Password
User-Profile
For example, the following commands set the Telnet password to dpg01!:
admin> read ip-global
IP-GLOBAL read
admin> set telnet-password = dpg01!
admin> write
IP-GLOBAL written
When a Telnet password has been specified, the system requires a two-tier password
authentication for Telnet logins, first the Telnet password, then the username and its
associated password. For example:
% telnet 1.1.1.1
<stinger01> Enter Password: dpg01!
Trying 1.1.1.1...
Connected to 1.1.1.1
Escape character is '^]'.
User: admin
Password: **********
If the user enters an incorrect Telnet password, the system prompts again, allowing
up to three attempts before timing out. If the user specifies the correct password, the
connection is established and the user is prompted to enter the name and password
of a valid User profile.
Stinger® MRT Getting Started Guide
Configuring Administrative Access, System Timing, and Startup Settings
Setting
Text string of up to 20 characters, required from all users
requesting a Telnet session. A user is allowed three
attempts, with 60 seconds per attempt, to enter the correct
password. A third unsuccessful attempt terminates the
login process. The value is case sensitive.
Name of a default User profile for authenticating all Telnet
logins. If no name is specified, the system prompts the user
to enter the name of a User profile.
Restricting administrative access
6-5