Lucent Technologies Stinger MRT 19 Getting Started Manual page 159

Table of Contents

Advertisement

Parameter
do-version-fallback
ignore-lineup
Stinger® MRT Getting Started Guide
Configuring T1 and E1 Trunk Modules
Setting
Specifies whether the Stinger MRT automatically falls
back to the earlier version of IMA if the far-end unit is
detected to be running the earlier version. If No is
specified when an earlier version is detected, the unit
moves to the configAborted state.
Valid values are as follows:
Yes—Specifies that the unit falls back from
version 1.1 to version 1.0.
No—Specifies that the unit does not fall back, but
moves to the configAborted state. This is the
default.
This parameter is used differently in the System
profile and in the Line profile.
In the System profile, specifies whether the Stinger MRT
unit ignores line status when determining whether
calls are established.
In the Line profile specifies whether the line status of a
slot determines the Stinger call-control mechanism on
a specified port.
In the System profile, specify one of the following values
for this parameter:
no—The Stinger call-control mechanism allows
calls to be established when the line state is UP
and disallow calls when the line state is DOWN.
This is the default.
yes—The Stinger call-control mechanism ignores
the line state and allows calls to be established on
a port as long as the specified slot is operational
and the specified port is enabled.
In the Line profile, specify one of the following values
for this parameter:
system-defined—Sets the Stinger MRT to inherit
the Ignore-Lineup value from the System profile.
This is the default.
no—Sets the Stinger call-control mechanism to
ignore the system-wide Ignore-Lineup setting and
allows calls to be established when the line state is
operational and disallow calls on the port when
the line state is DOWN.
yes—Sets the Stinger call-control mechanism to
ignore both the line state and the system-wide
setting and allows calls to be established on the
specified port as long as the specified slot is
operational and the specified port is enabled.
IMAgroup profile
9-17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Stinger mrt 23

Table of Contents