Profile
IMAgroup
IMAHW-Config
IMA-Group-Stat
Connection

DS1-ATM profile

Following are the parameters for the DS1-ATM profile, shown with sample settings.
[in DS1-ATM/{ shelf-1 slot-18 1 }]
name = 1:18:1
physical-address* = { shelf-1 slot-18 1 }
enabled = no
sparing-mode = inactive
line-config = { esf b8zs 109 no-loopback not-eligible high-priority none
no-cod+
[in DS1-ATM/{ shelf-1 slot-18 9 }:line-config]
frame-type = esf
encoding = b8zs
nailed-group = 109
loopback = no-loopback
clock-source = not-eligible
clock-priority = high-priority
FDL = none
send-code = no-code
front-end-type = short-haul
line-length = 1-133
line-build-out = 0-db
pcm-mode = clear-channel
coset-enabled = yes
scrambling-enabled = no
hec-correction-enabled = no
vp-switching-vpi = 15
ima-option-config = { { 8 3 fast auto 10 0 } { 3 fast 10 100 auto 10 2500
10000+
Stinger® MRT Getting Started Guide
Description
Created when you enter the command new imagroup to
establish an IMA port. All group-related IMA parameters
are stored in this profile. For more information, see
"IMAgroup profile" on page 9-15.
Used to configure hardware-specific parameters that are
common to the IMA chip. For more information, see
"IMAHW-Config profile" on page 9-20.
Created only after you have properly configured an
imagroup profile and associated DS1-ATM profile. Use this
profile to determine the status and statistics for an IMA
group. For more information, see "IMA-Group-Stat profile"
on page 9-21.
Used to configure connection-specific information. For
more information, see "Connection profile" on page 9-25.