Configuring T1 and E1 Trunk Modules
Connection profile
clid = ""
auto-profile = yes
ip-options = { yes yes 0.0.0.0/0 0.0.0.0/0 1 60 120 no 0 0.0.0.0 routing-off ""+
bridging-options = { 0 no }
session-options = { "" "" no 120 no-idle 120 "" 0 disabled autobaud 784000 9280+
telco-options = { ans-and-orig no ft1 1 no no 56k-clear 0 "" "" no 0 any }
ppp-options = { no-ppp-auth none "" none "" "" "" "" stac 1524 no 600 600 no 15+
mp-options = { 1 1 2 }
mpp-options = { "" quadratic transmit 1 1 15 5 10 70 }
fr-options = { "" 16 "" transparent-link no "" 16 "" }
tcp-clear-options = { "" 0 "" 0 "" 0 "" 0 no "" 0 0 }
answer-options = { }
usrRad-options = { global 0.0.0.0 1646 "" 1 acct-base-10 }
calledNumber = ""
cross-connect-index = 0
atm-options = { aal5-llc 0 35 1 p2p pvc no
00:00:00:00:00:00:00:00:00:00:00:00:+
atm-connect-options = { aal5-llc 0 35 1 p2p pvc no
00:00:00:00:00:00:00:00:00:0+
atm-qos-options = { default default }
atm-aal-options = { no aal-0 1 1 }
conn-user = default
..
Parameter
station
active
encapsulation-
protocol
9-26
Setting
In a Connection profile, specifies the name of the CPE or
remote device on the inbound side of the circuit.
You can enter up to 31 characters. The value you specify is
case sensitive, and must exactly match the name of the
remote device. If you are not sure about the exact name,
contact the administrator of the remote network. The
default is null.
Enable/disable the connection. You must change the
default (no) value to yes to activate the connection for use.
Specifies the encapsulation method to use for the
connection. Both sides of the connection must support the
specified encapsulation method. Usually, encapsulation
protocols have their own configuration options within the
subprofile of a Connection profile.
Specify one of the following values:
ATM—Specifies an ATM connection in routed mode.
Packets arriving on the connection are routed at OSI
Layer 3.
ATM-Circuit—Specifies point-to-point switch-through
ATM connections. This is the default.
ATM-Frame-Relay-Circuit—Specifies an ATM-to-frame
relay link.
ATM-IMA—Specifies an ATM IMA link.