Lucent Technologies Stinger MRT 19 Getting Started Manual page 148

Table of Contents

Advertisement

Configuring T1 and E1 Trunk Modules
DS1-ATM profile
[in DS1-ATM/{ shelf-1 slot-18 1 }:line-config:ima-option-config]
txlink-config = { 8 3 fast auto 10 0 }
rxlink-config = { 3 fast 10 100 auto 10 2500 10000 10 }
Parameter
name
physical-address
enabled
sparing-mode
line-config
line-config:frame-type
line-config:encoding
line-config:nailed-group
9-6
Setting
Assigns a name to the DS1-ATM profile. Specify a
descriptive name with no embedded spaces.
Identifies the physical location of the DS1-ATM line
within the Stinger MRT system, in the format
{shelf slot item}. On a Stinger MRT, the shelf number is
always 1 and the T1 or E1 slot number is always 18.
The item number indicates the line number. The
system supplies the value for this parameter.
Specifies whether this DS1-ATM interface is enabled
or disabled.
Valid values are as follows:
Yes—Specifies that the interface is enabled.
No—Specifies that the interface is disabled. This is
the default.
Not used on the Stinger MRT
A subprofile containing line configuration options for
the DS1-ATM link.
The super-framing mode that is used on the physical
link.
Valid values are as follows:
d4 (T1 only)
esf (T1 only)
g703 (E1 only)
The Layer 1 line encoding used for the physical link.
Valid values are as follows:
ami (T1 only)
b8zs (T1 only)
hdb3 (E1 only)
Specifies the group index that this link belongs to, a
numeric value from 1 through 2048.
Stinger® MRT Getting Started Guide